Stability of Bilateral Sagittal Split Ramus Osteotomy (BSSRO) using adjustable mandibular plates in adjunction with bicortical screws versus traditional positional screws for antero-posterior mandibular deficient patients. (randomized clinical trial) / Marwa Ragaey Abdelhakam Mahmoud ; Supervised Emad Saeed Helmy Amin , Joseph Edward Van Sickels , Mohamed Ahmed Farid

By: Contributor(s): Material type: TextTextLanguage: English Publication details: Cairo : Marwa Ragaey Abdelhakam Mahmoud , 2017Description: 80 , (35 ) P. : facsmilies , photographs ; 25cmOther title:
  • استقرارالانقسام العظمى السهمى الثنائى باستخدام شرائح الفك السفلى القابله للتعديل بالاضافة الى المسامير القشرية الثنائية مقارنه بالمسامير الموضوعية التقليدية لمرضى نقص الفك السفلى الامامى الخلفى : تجربة سريريه عشوائية [Added title page title]
Subject(s): Online resources: Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (Ph.D) - Cairo University - Faculty of Oral and Dental Medicine - Department of Oral and Maxillofacial Surgery Summary: This study was performed to compare between stability bicortical screw versus the adjustable plating system in addition to 3 bicortical screws versus fixation after bilateral sagittal split osteotomy ( BSSO). The current study was a randomized clinical trial which included 12 patients, 5 males and 7 females, with age ranging from 15-56 years old suffering from mandibular retrognathism and indicated for mandibular advancement referred to the outpatient clinic of Oral and Maxillofacial Surgery department, Faculty of Dentistry, University of Kentucky, KY, USA
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Copy number Status Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.13.Ph.D.2017.Ma.S (Browse shelf(Opens below)) Not for loan 01010110081654000
CD - Rom CD - Rom مخـــزن الرســائل الجـــامعية - البدروم المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.13.Ph.D.2017.Ma.S (Browse shelf(Opens below)) 81654.CD Not for loan 01020110081654000
Browsing المكتبة المركزبة الجديدة - جامعة القاهرة shelves Close shelf browser (Hides shelf browser)
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
Cai01.09.13.Ph.D.2017.Ab.E Evaluation of complication rates following frontal sinus obliteration using anterior iliac crest bone versus abdominal fat graft for the management of frontal sinus fractures : Apreliminary randomized clinical trial / Cai01.09.13.Ph.D.2017.Ma.E Evaluation of stability by using a combination of one microplate and one miniplate versus two miniplates for reduction and fixation of parasymphyseal mandibular fracture RCT / Cai01.09.13.Ph.D.2017.Ma.E Evaluation of stability by using a combination of one microplate and one miniplate versus two miniplates for reduction and fixation of parasymphyseal mandibular fracture RCT / Cai01.09.13.Ph.D.2017.Ma.S Stability of Bilateral Sagittal Split Ramus Osteotomy (BSSRO) using adjustable mandibular plates in adjunction with bicortical screws versus traditional positional screws for antero-posterior mandibular deficient patients. (randomized clinical trial) / Cai01.09.13.Ph.D.2017.Ma.S Stability of Bilateral Sagittal Split Ramus Osteotomy (BSSRO) using adjustable mandibular plates in adjunction with bicortical screws versus traditional positional screws for antero-posterior mandibular deficient patients. (randomized clinical trial) / Cai01.09.13.Ph.D.2017.Mo.C Computer guided maxillary-zygomatic advancement versus conventional model surgery in mid-face deficiency : A randomized clinical trial / Cai01.09.13.Ph.D.2017.Mo.C Computer guided maxillary-zygomatic advancement versus conventional model surgery in mid-face deficiency : A randomized clinical trial /

Thesis (Ph.D) - Cairo University - Faculty of Oral and Dental Medicine - Department of Oral and Maxillofacial Surgery

This study was performed to compare between stability bicortical screw versus the adjustable plating system in addition to 3 bicortical screws versus fixation after bilateral sagittal split osteotomy ( BSSO). The current study was a randomized clinical trial which included 12 patients, 5 males and 7 females, with age ranging from 15-56 years old suffering from mandibular retrognathism and indicated for mandibular advancement referred to the outpatient clinic of Oral and Maxillofacial Surgery department, Faculty of Dentistry, University of Kentucky, KY, USA

Issued also as CD

There are no comments on this title.

to post a comment.

Click on an image to view it in the image viewer

Local cover image