Evaluation of accuracy of computer guided arthrocentesis for patients with anterior disc displacement with reduction of tmj using patient specific guide (PSV) : Case series / Kareem Mahmoud Kamal ; Supervised Nadia Galal , Mohamed Mounir , Sherif Ali

By: Contributor(s): Material type: TextTextLanguage: English Publication details: Cairo : Kareem Mahmoud Kamal , 2020Description: 126 P. : charts , facsimiles ; 25cmOther title:
  • تقييم دقه الجراحه الموجهة بالكمبيوترلبزل مفصل الفك الصدغى لمرضى انزياح غضروف مفصل الفك الردود باستخدام دليل المريض [Added title page title]
Subject(s): Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Oral and Maxillofacial Surgery Summary: Purpose: The aim of this study is to evaluate the accuracy of 3D printed patient- specific guide to direct the passage of inlet and outlet needles into the superior joint space of the temporomandibular joint (TMJ) during TMJ arthrocentesis. Methods: This study included eight patients with twelve TMJs with anterior disc displacement with reduction. A 3D patient- specific guide was designed for each patient to direct the inlet and outlet needles into the hidden superior joint space of the TMJ. The guides were implemented, and its accuracy to lead the needles into the superior joint space was assessed. Results: Both arthroscopic verification and clinical evaluation revealed direct and safe access to all the predetermined anatomic locations in the TMJs, except in one case, during which the patient failed to maintain the maximum mouth opening during CT scanning and the guide mapping was compromised
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Copy number Status Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.13.M.Sc.2020.Ka.E (Browse shelf(Opens below)) Not for loan 01010110082113000
CD - Rom CD - Rom مخـــزن الرســائل الجـــامعية - البدروم المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.13.M.Sc.2020.Ka.E (Browse shelf(Opens below)) 82113.CD Not for loan 01020110082113000

Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Oral and Maxillofacial Surgery

Purpose: The aim of this study is to evaluate the accuracy of 3D printed patient- specific guide to direct the passage of inlet and outlet needles into the superior joint space of the temporomandibular joint (TMJ) during TMJ arthrocentesis. Methods: This study included eight patients with twelve TMJs with anterior disc displacement with reduction. A 3D patient- specific guide was designed for each patient to direct the inlet and outlet needles into the hidden superior joint space of the TMJ. The guides were implemented, and its accuracy to lead the needles into the superior joint space was assessed. Results: Both arthroscopic verification and clinical evaluation revealed direct and safe access to all the predetermined anatomic locations in the TMJs, except in one case, during which the patient failed to maintain the maximum mouth opening during CT scanning and the guide mapping was compromised