Evaluation of lateral response of tall Building with new proposed outrigger locations / Mahmoud Mohammed Mahmoud Eisa Eisa ; Supervised Adel Y. Akl , Mostafa M. Elsayed

بواسطة: المساهم: نوع المادة : نصاللغة: الإنجليزية تفاصيل النشر: Cairo : Mahmoud Mohammed Mahmoud Eisa Eisa , 2020الوصف: 163 P. : charts , facsimiles ; 30cmعنوان آخر:
  • تقييم إستجابة المبانى الشاهقه للإزاحة الجانبية ذات أماكن جديدة مقترحة للكمرات العَرضِية الرابطة [عنوان مضاف عنوان الصفحة]
الموضوع: موارد على الإنترنت: Available additional physical forms:
  • Issued also as CD
ملاحظة الأطروحة: Thesis (M.Sc.) - Cairo University - Faculty of Engineering - Department Civil Engineering ملخص: Choosing the locations of outriggers along the height of buildings is mainly based on reducing the fundamental period of it, and thus the overturning moments. In this study, an alternative procedure is proposed to allocate outriggers along the height of the build-ing. The proposed procedure aims to reduce the difference in periods between the first two orthogonal modes of concerned structure, and thus to reduce the contribution of the twisting effect. In order to verify the accuracy of this procedure, four building heights are considered herein.These heights are numerically modeled creating almost a hundred 3D nonlinear finite-element models considering both traditional and proposed outrigger allocation techniques. First, modal properties are developed for the investigated struc-tures to ensure the effectiveness of using the new procedure in reducing the twisting moments. Next, seven different earthquake records, with six peak ground accelerations, are applied to previously mentioned structures and expected response is evaluated. Fi-nally, probability of different damage states is to establish using fragility curves consid-ering both traditional and proposed procedures utilized in allocating outriggers. The re-sults indicate that systems which use the proposed technique have stability and efficien-cy more than counterparts in the resistance of lateral excitation
وسوم من هذه المكتبة: لا توجد وسوم لهذا العنوان في هذه المكتبة. قم بتسجيل الدخول لإضافة الوسوم.
التقييم باستخدام النجوم
    متوسط التقييم: 0.0 (0 صوتًا)
المقتنيات
نوع المادة المكتبة الحالية المكتبة الرئيسية رقم الاستدعاء رقم النسخة حالة الباركود
Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.13.05.M.Sc.2020.Ma.E (استعراض الرف(يفتح أدناه)) لا تعار 01010110083008000
CD - Rom مخـــزن الرســائل الجـــامعية - البدروم المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.13.05.M.Sc.2020.Ma.E (استعراض الرف(يفتح أدناه)) 83008.CD لا تعار 01020110083008000

Thesis (M.Sc.) - Cairo University - Faculty of Engineering - Department Civil Engineering

Choosing the locations of outriggers along the height of buildings is mainly based on reducing the fundamental period of it, and thus the overturning moments. In this study, an alternative procedure is proposed to allocate outriggers along the height of the build-ing. The proposed procedure aims to reduce the difference in periods between the first two orthogonal modes of concerned structure, and thus to reduce the contribution of the twisting effect. In order to verify the accuracy of this procedure, four building heights are considered herein.These heights are numerically modeled creating almost a hundred 3D nonlinear finite-element models considering both traditional and proposed outrigger allocation techniques. First, modal properties are developed for the investigated struc-tures to ensure the effectiveness of using the new procedure in reducing the twisting moments. Next, seven different earthquake records, with six peak ground accelerations, are applied to previously mentioned structures and expected response is evaluated. Fi-nally, probability of different damage states is to establish using fragility curves consid-ering both traditional and proposed procedures utilized in allocating outriggers. The re-sults indicate that systems which use the proposed technique have stability and efficien-cy more than counterparts in the resistance of lateral excitation

Issued also as CD

لا توجد تعليقات على هذا العنوان.

اضغط على الصورة لمشاهدتها في عارض الصور

صورة الغلاف المحلية
شارك
Cairo University Libraries Portal Implemented & Customized by: Eng. M. Mohamady Contacts: new-lib@cl.cu.edu.eg | cnul@cl.cu.edu.eg
CUCL logo CNUL logo
© All rights reserved — Cairo University Libraries
CUCL logo
Implemented & Customized by: Eng. M. Mohamady Contact: new-lib@cl.cu.edu.eg © All rights reserved — New Central Library
CNUL logo
Implemented & Customized by: Eng. M. Mohamady Contact: cnul@cl.cu.edu.eg © All rights reserved — Cairo National University Library