Seismic resilience quantification of a hospital designed according to ECP-201 / Heidi Yosri Mohammad Hosni Ibrahim ; Supervised Walid Abdellatif Attia
Material type:
- قياس الصمود الزلزالى والرجوعية لمستشفى مصممة طبقا للكود المصرى (201 [Added title page title]
- Issued also as CD
Item type | Current library | Home library | Call number | Copy number | Status | Barcode | |
---|---|---|---|---|---|---|---|
![]() |
قاعة الرسائل الجامعية - الدور الاول | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.13.05.M.Sc.2021.He.S (Browse shelf(Opens below)) | Not for loan | 01010110083867000 | ||
![]() |
مخـــزن الرســائل الجـــامعية - البدروم | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.13.05.M.Sc.2021.He.S (Browse shelf(Opens below)) | 83867.CD | Not for loan | 01020110083867000 |
Browsing المكتبة المركزبة الجديدة - جامعة القاهرة shelves Close shelf browser (Hides shelf browser)
No cover image available | No cover image available | No cover image available | No cover image available | No cover image available | No cover image available | No cover image available | ||
Cai01.13.05.M.Sc.2021.Ha.P Pressure dependency of resedimented nile silty clay / | Cai01.13.05.M.Sc.2021.Ha.P Pressure dependency of resedimented nile silty clay / | Cai01.13.05.M.Sc.2021.He.S Seismic resilience quantification of a hospital designed according to ECP-201 / | Cai01.13.05.M.Sc.2021.He.S Seismic resilience quantification of a hospital designed according to ECP-201 / | Cai01.13.05.M.Sc.2021.Ho.C Calibration to the seismic provisions for steel momentresisting frames in the new proposed Egyptian code for steel structures / | Cai01.13.05.M.Sc.2021.Ho.C Calibration to the seismic provisions for steel momentresisting frames in the new proposed Egyptian code for steel structures / | Cai01.13.05.M.Sc.2021.Ho.U Use of steel fibers to enhance mechnical properties of concrete subjected to high temperatures / |
Thesis (M.Sc.) - Cairo University - Faculty of Engineering - Department of Civil Engineering
This thesis presents seismic resilience quantification of a hospital designed according to the Egyptian code (ECP-201) in terms of repair cost, repair time and casualties. The prototype building is an existed typical 5-story reinforced concrete structure with shear walls and expansion joint, located in Suez. Building{u2019}s safety against lateral loads was checked according to ECP-201 provisions.Static non-linear (Pushover) analysis was conducted. Collapse fragility functions of building{u2019}s structural and non-structural components were established using incremental dynamic analysis (IDA). Building{u2019}s seismic resilience was quantified using new-generation seismic performance assessment methodology proposed by Federal Emergency Management Agency (FEMA), FEMA P-58 along with its associated software, Performance Assessment Calculation Tool (PACT). The outcomes show that building{u2019}s median repair time is 22 days, median repair cost is $20,850,000 which is 66.5% of the building{u2019}s total replacement cost, and median number of causalities is 386 persons
Issued also as CD
There are no comments on this title.