Patient specific three-dimensional titanium plates versus conventional miniplates for the treatment of mandibular body fractures : Randomized clinical trial / Dina Adel Alei Eldine Thaalab ; Supervised Mohamed Ahmed Farid Shehab , Mohamed Atef Abdelrassoul

By: Contributor(s): Material type: TextTextLanguage: English Publication details: Cairo : Dina Adel Alei Eldine Thaalab , 2019Description: 107 P. : charts , facsimiles ; 25cmOther title:
  • دراسة المقارنة بين الشرائح التيتانيوم ثلاثية ألابعاد المخصصة للمريض و الشرائح المينى التقليدية لعلاج كسور جسم الفك السفلى : دراسة سريرية عشوائية [Added title page title]
Subject(s): Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Oral and Maxillofacial Surgery Summary: Aim: The aim of the current study is to evaluate and assess the clinical stability and efficacy of patient specific 3D computer guided titanium plates versus the conventional titanium mini plates for accurate reduction and fixation of mandibular body fractures. Methodology : Twenty patients were selected suffering from isolated mandibular body fractures, divided blindly and randomly into two equal groups, Group I was treated with patient specific 3D titanium plates, Group II was treated with Conventional miniplates.Clinical evaluation included; patient satisfaction, Pain, occlusion and occlusal bite force. Radiographic parameter evaluated was fracture gap distance. All parameters were evaluated at One week and 3 months intervals.The Operating time was also measured during the surgery. Results: Group I have shown higher values of patient satisfaction scores and lower pain scores than group II at both one week and 3 months intervals.The degree of occlusal derangement has shown no statistically significant difference between both groups at one week postoperatively, while both groups have shown normal occlusion after 3 months. Occlusal bite forces in Group I were significantly higher than group II at one week and 3 months intervals.The fracture gap distance was statistically insignificant between both groups at one week and 3 months intervals. The operating time was significantly lower for Group I than Group II
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Copy number Status Date due Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.13.M.Sc.2019.Di.P (Browse shelf(Opens below)) Not for loan 01010110084268000
CD - Rom CD - Rom مخـــزن الرســائل الجـــامعية - البدروم المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.13.M.Sc.2019.Di.P (Browse shelf(Opens below)) 84268.CD Not for loan 01020110084268000
Browsing المكتبة المركزبة الجديدة - جامعة القاهرة shelves Close shelf browser (Hides shelf browser)
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
Cai01.09.13.M.Sc.2019.Al.C Conventional versus computer guided surgical removal of deeply impacted mandibular third molar : Arandomized clinical trial : Comparative study / Cai01.09.13.M.Sc.2019.Al.E Evaluation of the effect of solcoseryl on promotion of bone regeneration in calvarial bony defect : An experimental pilot study / Cai01.09.13.M.Sc.2019.Al.E Evaluation of the effect of solcoseryl on promotion of bone regeneration in calvarial bony defect : An experimental pilot study / Cai01.09.13.M.Sc.2019.Di.P Patient specific three-dimensional titanium plates versus conventional miniplates for the treatment of mandibular body fractures : Randomized clinical trial / Cai01.09.13.M.Sc.2019.Di.P Patient specific three-dimensional titanium plates versus conventional miniplates for the treatment of mandibular body fractures : Randomized clinical trial / Cai01.09.13.M.Sc.2019.Mi.E Evaluation of the accuracy of CAD-CAM custom made titanium miniplates in positioning of the genial segment in computer guided genioplasty : Pilot study / Cai01.09.13.M.Sc.2019.Mi.E Evaluation of the accuracy of CAD-CAM custom made titanium miniplates in positioning of the genial segment in computer guided genioplasty : Pilot study /

Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Oral and Maxillofacial Surgery

Aim: The aim of the current study is to evaluate and assess the clinical stability and efficacy of patient specific 3D computer guided titanium plates versus the conventional titanium mini plates for accurate reduction and fixation of mandibular body fractures. Methodology : Twenty patients were selected suffering from isolated mandibular body fractures, divided blindly and randomly into two equal groups, Group I was treated with patient specific 3D titanium plates, Group II was treated with Conventional miniplates.Clinical evaluation included; patient satisfaction, Pain, occlusion and occlusal bite force. Radiographic parameter evaluated was fracture gap distance. All parameters were evaluated at One week and 3 months intervals.The Operating time was also measured during the surgery. Results: Group I have shown higher values of patient satisfaction scores and lower pain scores than group II at both one week and 3 months intervals.The degree of occlusal derangement has shown no statistically significant difference between both groups at one week postoperatively, while both groups have shown normal occlusion after 3 months. Occlusal bite forces in Group I were significantly higher than group II at one week and 3 months intervals.The fracture gap distance was statistically insignificant between both groups at one week and 3 months intervals. The operating time was significantly lower for Group I than Group II

Issued also as CD

There are no comments on this title.

to post a comment.