Power system operation in the presence of flexible prosumers considering system congestion / Mayar Mohsen Mostafa Madboly ; Supervised Mohamed Salah Elsobki , Amgad Amin Eldeib

By: Contributor(s): Material type: TextTextLanguage: English Publication details: Cairo : Mayar Mohsen Mostafa Madboly , 2021Description: 126 P. : charts ; 30cmOther title:
  • التشغيل الأمثل لنظم القوى الكهربية فى وجود الأحمال المرنة وأثناء اختناقات النظام [Added title page title]
Subject(s): Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (M.Sc.) - Cairo University - Faculty of Engineering - Department of Electrical Power and Machines Summary: In this thesis, the optimal operation of the power system is studied using different objective functions: minimum total generation cost, minimum active power losses, minimum specific generation cost, minimum average energy cost. The effect of congestion on the voltage and reactive power output as well as the system performance is analyzed. The system performance is assessed through some key performance indices. Two IEEE benchmark systems which are IEEE 5-bus and 14-bus systems were used to test the formulations and algorithms. The model also includes variable loads and prosumers whose presence proved to be effective in dealing with power system congestion.The use of flexible loads and prosumers benefited the power system by reducing the system costs and losses. Additionally, the voltage profile of the system was enhanced
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Copy number Status Date due Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.13.07.M.Sc.2021.Ma.P (Browse shelf(Opens below)) Not for loan 01010110084485000
CD - Rom CD - Rom مخـــزن الرســائل الجـــامعية - البدروم المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.13.07.M.Sc.2021.Ma.P (Browse shelf(Opens below)) 84485.CD Not for loan 01020110084485000

Thesis (M.Sc.) - Cairo University - Faculty of Engineering - Department of Electrical Power and Machines

In this thesis, the optimal operation of the power system is studied using different objective functions: minimum total generation cost, minimum active power losses, minimum specific generation cost, minimum average energy cost. The effect of congestion on the voltage and reactive power output as well as the system performance is analyzed. The system performance is assessed through some key performance indices. Two IEEE benchmark systems which are IEEE 5-bus and 14-bus systems were used to test the formulations and algorithms. The model also includes variable loads and prosumers whose presence proved to be effective in dealing with power system congestion.The use of flexible loads and prosumers benefited the power system by reducing the system costs and losses. Additionally, the voltage profile of the system was enhanced

Issued also as CD

There are no comments on this title.

to post a comment.