Comparative study between measurements of limbal insertion distance of horizontal extraocular muscles with preoperative as-oct measurement in adult strabismus patients / Mohamed Ibrahim Shoeib ; Supervised Nihal Adel Hassan , Mohamed Mahmoud Khafagi , Nermeen Mostafa Bahgat
Material type: TextLanguage: English Publication details: Cairo : Mohamed Ibrahim Shoeib , 2021Description: 74 P. : charts , facsimiles ; 25cmOther title:- درا{uئإآ٣}{uئإ٩٤} {uئإإ٣}{uئإؤ٨}{uئإ٨إ}ر{uئإإ٧}{uئإ٩٤} {uئإ٩١}{uئإئ٣}ن ا{uئإؤئ}{uئإؤ٨}{uئإئ٣}{uئإ٨إ}{uئإآ٣}{uئإ٨إ}ت {uئإؤئ}{uئإإ٣}{uئإآ٣}{uئإ٨إ}{uئإؤ٣}{uئإ٩٤} {uئإإ٣}{uئإؤ٠}رز ا{uئإؤئ}{uئإأأ}{uئإآئ}{uئإئأ}ت ا{uئإؤئ}{uئإء٧}{uئإ٨إ}ر{uئإ٩ئ}{uئإئ٣}{uئإ٩٤} ا{uئإئآ}{uئإؤ٣}{uئإؤ٨}{uئإئ٣}{uئإإء} {uئإؤئ}{uئإإ٠}{uئإأأ}{uئإئ٣}ن {uئإإ٣}ن {uئإء٣}د ا{uئإؤئ}{uئإآآ}{uئإإ٠}{uئإ٩١}{uئإإء} و{uئإؤ٧}{uئإئ٣}{uئإ٨إ}{uئإآ٣}{uئإ٨إ}ت {uئإإ٣}{uئإ٨إ} {uئإؤ٧}{uئإ٩١}{uئإؤؤ} ا{uئإؤئ}{uئإ٩ئ}را{uئإء٣}{uئإإء} {uئإ٩١}{uئإ٨إ}{uئإآ٣}{uئإ٩٧}{uئإء٧}دام {uئإ٩٧}{uئإآآ}و{uئإئ٣}ر ا{uئإؤئ}{uئإ٩ئ}زء ا{uئإئآ}{uئإإ٣}{uئإ٨إ}{uئإإ٣}{uئإئ٠} {uئإ٩١}{uئإ٨إ}{uئإؤئ}{uئإإ٣}{uئإ٨إ}{uئإآ٣}{uئإء٢} ا{uئإؤئ}{uئإإ٣}{uئإؤ٨}ط{uئإأأ}{uئإئ٠} ا{uئإؤئ}{uئإآئ}و{uئإ٨آ}{uئإئ٠} {uئإؤ٣}{uئإئ٠} {uئإإ٣}ر{uئإآئ}{uئإئ٠} ا{uئإؤئ}{uئإء٣}و{uئإؤؤ} ا{uئإؤئ}{uئإ٩١}{uئإ٨إ}{uئإؤئ}{uئإؤ٠}{uئإئ٣}ن [Added title page title]
- Issued also as CD
Item type | Current library | Home library | Call number | Copy number | Status | Date due | Barcode | |
---|---|---|---|---|---|---|---|---|
Thesis | قاعة الرسائل الجامعية - الدور الاول | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.11.24.M.Sc.2021.Mo.C (Browse shelf(Opens below)) | Not for loan | 01010110084995000 | |||
CD - Rom | مخـــزن الرســائل الجـــامعية - البدروم | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.11.24.M.Sc.2021.Mo.C (Browse shelf(Opens below)) | 84995.CD | Not for loan | 01020110084995000 |
Browsing المكتبة المركزبة الجديدة - جامعة القاهرة shelves Close shelf browser (Hides shelf browser)
Thesis (M.Sc.) - Cairo University - Faculty of Medicine - Department of Ophthalmology
Purpose: To investigate the accuracy of AS-OCT in imaging EOMs insertion as compared with intraoperative measurement by the caliper.Methods: thirty five out of forty patients completed a cross sectional observational study. All patients had a full strabismus examinations, were imaged by the AS-OCT, measurements were compared with intraoperative measurements. Results: imaging of MR muscles showed no significant difference as compared with the intraoperative measurements P value (0.593) in MR ofRT eye, P Value (0.110) in MR of LT eye however imaging of LR muscle showed significant difference as compared with the intraoperative measurements (p-value 0.001) in LR of RT eye, P-Value <0.001) Age, gender, axial length showed no significance.Conclusion: In this comparative study, the AS-OCT is a non-contact, easily used; highly accurate investigative tool in imaging MR. However its accuracy may be limited by the machine beam's length used on imaging a muscle like LR inserted mostly very close to the machine beam's length, AS-OCT is also not effective investigative tool for patient with poor fixation and incooperative ones