Effect of different voxel sizes on accuracy of 2D and 3D mandibular linear measurements using cranex® 3D cone beam computed tomography machine : Preclinical study / Mohamed Ahmed Mohamed Selim ; Supervised Mushira Mohamed Dahaba , Ahmad M. Abdalsamad
Material type:
- للتصو{u٠٦أأ}رالمقطعى بالحاسوب مخروطى الشعاع CRANEX® 3D تأث{u٠٦أأ}راختلاف وحدات الحجم على دقة الق{u٠٦أأ}اسات الخط{u٠٦أأ}ه ثنائ{u٠٦أأ}ة وثلاث{u٠٦أأ}ة الأبعاد بالفك السفلى : دراسة قبل السريرية [Added title page title]
- Issued also as CD
Item type | Current library | Home library | Call number | Copy number | Status | Barcode | |
---|---|---|---|---|---|---|---|
![]() |
قاعة الرسائل الجامعية - الدور الاول | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.09.05.M.Sc.2019.Mo.E (Browse shelf(Opens below)) | Not for loan | 01010110085062000 | ||
![]() |
مخـــزن الرســائل الجـــامعية - البدروم | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.09.05.M.Sc.2019.Mo.E (Browse shelf(Opens below)) | 85062.CD | Not for loan | 01020110085062000 |
Browsing المكتبة المركزبة الجديدة - جامعة القاهرة shelves Close shelf browser (Hides shelf browser)
Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine- Department of Radiology and Diagnosis
Aim To assess the accuracy of linear measurement obtained from CBCT images in 3D volumetric rendering and multiplanar slices with different voxel sizes. Methodology: 9 mandibles with twelve radio opaque markers fixed on each one were imaged using CRANEX® 3D (Soredex Oy, Tuusula, Finland) CBCT machine. Each mandible was imaged twice with voxel sizes 250 om and 350 om. 2D and 3D linear measurements obtained from the CBCT software were compared to the real physical measurements taken by a digital caliper. Software measurements were recorded twice by the principal investigator and once by the supervising professor. Intra- and inter-observer agreements were assessed using Intra-Class Correlation Coefficient (ICC). SPSS®IBM Version 24 and MedCalc® version 12.1 for Windows were used for statistical analysis. Results: CBCT 2D measurements with voxel sizes of 250o and 350o showed a mean difference= 0 mm both with 95% of difference being -0.6 mm above or 0.7mm below and-0.5 mm above or 0.6 mm below the Gold Standard respectively. CBCT 3D measurements with voxel sizes of 250o and 350o showed a mean difference= 0 mm both with 95% of difference being -0.5 mm below or 0.5 mm above and -0.6 mm above or 0.7 mm below the Gold Standard. Intra-observer and inter-observer reliability regarding all measurements showed excellent agreement. Conclusions: 2D and 3D measurements driven from CBCT images with voxel size of 350 o are accurate as measurements driven from CBCT images with voxel size of 250 o with less radiation delivered to the patient. 3D measurements driven from CBCT are as accurate as 2D measurements. 2D and 3D CBCT measurements driven from CBCT are reliable
Issued also as CD