Effect of different surface treatment protocols on the retention of posterior peek crowns : A randomized invitro study / Kareem Mohamed Abdelmotaleb ; Supervised Hesham Katamesh , Reham Saeed Elbasty
Material type:
- تأثير المعالجات السطحيه المختلفه علي الاستبقاء للتيجان المصنوعه من ماده البيك : دراسه معمليه [Added title page title]
- Issued also as CD
Item type | Current library | Home library | Call number | Copy number | Status | Barcode | |
---|---|---|---|---|---|---|---|
![]() |
قاعة الرسائل الجامعية - الدور الاول | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.09.09.M.Sc.2021.Ka.E (Browse shelf(Opens below)) | Not for loan | 01010110085241000 | ||
![]() |
مخـــزن الرســائل الجـــامعية - البدروم | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.09.09.M.Sc.2021.Ka.E (Browse shelf(Opens below)) | 85241.CD | Not for loan | 01020110085241000 |
Browsing المكتبة المركزبة الجديدة - جامعة القاهرة shelves Close shelf browser (Hides shelf browser)
Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics
Aim: The purpose of this study is to evaluate the retention of PEEK-based posterior crowns after different surface treatment protocols (sandblasting using 110 micron alumina particles, acid etching using sulphuric acid and combined sandblasting and acid etching). Methodology: 24 extracted human natural molars that were mounted in epoxy blocks and they were prepared to receive PEEK copings that were divided into 3 groups. The first group was treated with sandblasting with 110 micron alumina particles under 2 bar, The second group was treated with 98% sulphuric acid for 60 secondsthen rinsed with running water for 60 seconds, The third group was treated with sandblasting and acid etching together then all copings were cemented to their correspondingteeth with Relyx Ultimate clicker then after cementation all copings were subjected to a pull out test using a Universal testing machine . After the mesurments the teeth were examined under digital microscope to detect the mode of failure. Results:For Sandblasted group the mean ± SD values were (80.66± 5.54N) with minimum value (59.31 N) and maximum value (108.27 N), while for Acid etched group the mean ± SD values were (87.45± 5.56 N) with minimum value (81.96 N) and maximum value (101.34 N). Meanwhile the mean ± SD values for Sandblasted and Acid etched group together were (92.43± 5.51 N) with minimum value (79.67 N) and maximum value (106.19 N). In accordance to the mode of failure In SB and AE treated group, the failure mode pattern was predominantly adhesive while minority was mixed. In SB + AE treated group samples showed equal % between adhesive and mixed failure mode patterns.There was no record for cohesive failure mode pattern in all groups
Issued also as CD
There are no comments on this title.