header
Image from OpenLibrary

Perfusion index, intraocular pressure and haemodynamic responses to insertion of endotracheal tube, air-Q and ambu aura-i inophthalmic surgeries : Randomized controlled study / Islam Adel Mohammed Mohammed Eladl ; Suervised Nadia Youssef Hamed Helmy , Gihan Mohamed Obayah , Nader Noshy Naguib

By: Contributor(s): Material type: TextTextLanguage: English Publication details: Cairo : Islam Adel Mohammed Mohammed Eladl , 2021Description: 64 P. : charts , facsimiles ; 25cmOther title:
  • استجابات معامل التروية :ضغط العين : والديناميكية الحيوية لاستخدام وتركيب الأنبوبة الحنجرية :الأيركيو :والأمبو أورا أى : دراسة محكمة عشوائية [Added title page title]
Subject(s): Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (Ph.D.) - Cairo University - Faculty of Medicine - Department of Anaesthesia Summary: The Ambu Aura-I is a great alternative to the endotracheal tube for attaining and maintaining airway control during elective and emergency operations in patients who are candidates for a supraglottic airway or when alternative options aren't accessible or when other attempts to insert a secure airway have failed. It offers a number of advantages: anatomically correct curve is built-in for quick and easy implantation,standard endotracheal tubes can be used through it for intubation, the reinforced tip prevents the plugging of the upper esophageal sphincter and prevents it from folding over during establishment,occlusions are prevented by the bite resistance in the connector block, depth markers make it easy to keep track of the right position, the pilot balloon determines the mask size and offers a tactile indicator of the degree of inflation as well as navigation markers for the procedure of guiding the flexible scope
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Copy number Status Date due Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.11.01.Ph.D.2021.Is.P (Browse shelf(Opens below)) Not for loan 01010110085479000
CD - Rom CD - Rom مخـــزن الرســائل الجـــامعية - البدروم المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.11.01.Ph.D.2021.Is.P (Browse shelf(Opens below)) 85479.CD Not for loan 01020110085479000
Browsing المكتبة المركزبة الجديدة - جامعة القاهرة shelves Close shelf browser (Hides shelf browser)
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
Cai01.11.01.Ph.D.2021.Ha.R Randomized comparative trial of pre-surgical lumbar epidural analgesia with bilateral erector spinae block for perioperative pain management in lumbar spine surger / Cai01.11.01.Ph.D.2021.Ha.R Randomized comparative trial of pre-surgical lumbar epidural analgesia with bilateral erector spinae block for perioperative pain management in lumbar spine surger / Cai01.11.01.Ph.D.2021.Is.P Perfusion index, intraocular pressure and haemodynamic responses to insertion of endotracheal tube, air-Q and ambu aura-i inophthalmic surgeries : Randomized controlled study / Cai01.11.01.Ph.D.2021.Is.P Perfusion index, intraocular pressure and haemodynamic responses to insertion of endotracheal tube, air-Q and ambu aura-i inophthalmic surgeries : Randomized controlled study / Cai01.11.01.Ph.D.2021.Mi.A Analgesic efficacy of ultrasound guided erector spinae plane block versus fentanyl infusion in pediatric patients undergoing aortic coarctectomy : A randomized controlled study Cai01.11.01.Ph.D.2021.Mo.E Effectiveness of bilateral ultrasound-guided erector spinae plane block in intraoperative and postoperative pain control in lumbar spine surgeries / Cai01.11.01.Ph.D.2021.Mo.E Effectiveness of bilateral ultrasound-guided erector spinae plane block in intraoperative and postoperative pain control in lumbar spine surgeries /

Thesis (Ph.D.) - Cairo University - Faculty of Medicine - Department of Anaesthesia

The Ambu Aura-I is a great alternative to the endotracheal tube for attaining and maintaining airway control during elective and emergency operations in patients who are candidates for a supraglottic airway or when alternative options aren't accessible or when other attempts to insert a secure airway have failed. It offers a number of advantages: anatomically correct curve is built-in for quick and easy implantation,standard endotracheal tubes can be used through it for intubation, the reinforced tip prevents the plugging of the upper esophageal sphincter and prevents it from folding over during establishment,occlusions are prevented by the bite resistance in the connector block, depth markers make it easy to keep track of the right position, the pilot balloon determines the mask size and offers a tactile indicator of the degree of inflation as well as navigation markers for the procedure of guiding the flexible scope

Issued also as CD

There are no comments on this title.

to post a comment.