The effect of tympanic membrane perforation on real - ear to coupler difference acoustic transform function /
تأثير ثقب طبلة الاذن على وظيفة التحويل الصوتى فرق القياس بين الاذن الحقيقية ومتقارنتها هل2سم3
Hanaa Ahmed Fadel ; Supervised Mohamed Tarek Ghannoum , Mohamed Elbadr Eldabae , Abeir Osman Dabbous
- Cairo : Hanaa Ahmed Fadel , 2008
- 107P. : charts , facsimiles ; 25cm
Thesis (M.Sc.) - Cairo University - Faculty Of Medicine - Department Of E.N.T
RECD in patients with tympanic membrane perforation is lower than normal at frequencies (250 Hz - 750 Hz) we recommend that this discrepancy should be compensated for if average normal RECD are used in the pre - selection of target and gain to avoid under amplification at lower frequencies
Real - ear - to coupler difference RECD Tympanic membrane perforation