The effect of implant length and diameter on stress distribution of overdenture in kennedy class II cases : Three-dimensional finite element analysis /
تأثير طول و قطر الغرسة المعدنية على توزيع الضغوط في حالات التقسيم الثاني لكينيدي
Ashraf Ahmed Mohamed Saad ; Supervised Ashraf Emil Eskander , Maha Wagdi , Sahar Ali Fawzy
- Cairo : Ashraf Ahmed Mohamed Saad , 2009
- 127 Leaves : charts , facsimiles ; 30cm
Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics
A finite element analysis study was carried out to evaluate the effect of implant length and diameter on stresses distribution around an implant used as distal support in kennedy class II implant supported partial overdenture. It was found that the stresses in the surrounding structures decrease with the increase of both the implant length and diameter. The implant diameter was found to be more effective factor
Finite element analysis Kennedy class II cases Stresses