Tamer Helal Farahat

Clinical and radiographic assessment of efficacy of resorbable versus non-resorbable positional screw osteosynthesis for bilateral sagittal split ramus osteotomy B.S.S.R.O / تقييم إكلينيكي و شعاعي للمقارنة بين براغي التيتانيوم و البراغي ذاتية الإمتصاص في تثبيت الفلق السهمي لفرعي الفك السفلي : دراسة سريرية Tamer Helal Farahat ; Supervised Mohamed Galal Gamal Eldin Behery , Maguid Amin Mohamed Ahmed , Emad Saeed Helmy Amin - Cairo : Tamer Helal Farahat , 2010 - 117 Leaves : charts , facsimiles ; 30cm

Thesis (Ph.D.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Oral Surgery

The bilateral sagittal split ramus osteotomy is now known to be a versatile method for correction of different mandibular deformities. However the type of osteotomy fixation and its relation to postoperative skeletal relapse continues to be a common postoperative debate. Internal fixation using titanium hardware became the gold standard despite its possible need for its removal requiring a second surgery due to possible complications including unacceptable palpability or looseness



B.S.S.R.O Resorbable screws Sagittal split