Role of color doppler US versus triphasic CT with portography in differentiating benign from malignat portal vein thrombosis /
دور الموجات فوق الصوتية الملونة مقارنة بالاشعة المقطعية متعددة الكواشف ثلاثية المراحل فى التفرقة بين جلطات الوريد البابى الكبدي الحميدة و الخبيثة
Ahmed Elshennawy Zein Eldeen Elshennawy ; Supervised Khaled Mohammed Helmy Elkaffas , Ahmed Hosni Kamel
- Cairo : Ahmed Elshennawy Zein Eldeen Elshennawy , 2013
- 133 Leaves : facsimiles ; 25cm
Thesis (M.Sc.) - Cairo University - Faculty of Medicine - Department of Radio-diagnosis
This study was carried out on 30 patients with portal vein thrombosis to specify the nature of the thrombus whether malignant or benign, 24 patients were males (80%) and 6 were females (20%) with a mean age of 52.2 years. Grey scale U/S, tumor markers, doppler ultrasound and multidetector triphasic CT examination were performed to all patients and according to the grey scale U/S, tumor markers and FNAC from suspicious thrombi 16 patients had malignant portal vein thrombi and 14 patients had benign thrombi