Plastic instability of thin - walled clamped - clamped conical pipe reduces /
عدم الاستقرار اللدن لوصلات المواسير المخروطية رقيقة الجدار والمثبته من الطرفين
Ibrahim Emad Eldin Ahmed Awad ; Supervised Abdelrahman Ragab , Chahinaz Abdelrahman Saleh
- Cairo : Ibrahim Emad Eldin Ahmed Awad , 2013
- 49 P. : charts , facsimiles ; 30cm
Thesis (M.Sc.) - Cairo University - Faculty of Engineering - Department of Mechanical Design and Production
Flanged conical pipe reducer shells are studied . Due to the existence of this type of flanged connection local bending takes place at the assumed rigid locations that causes discontinuity local bending takes place at the assumed rigid locations that causes discontinuity stresses . Plastic instability pressure considered as burst pressure is obtained by the use of finite element method