The safety and efficacy of a short specially designed fully covered metallic stent in the management of benignpost surgical biliary strictures : A randomized controlled multicenter study /
سلامة وفعالية الدعامات المعدنية المغطاة بالكامل والمصممة خصيصًا فى علاج الضيق اقنوات المراريه بعد الجراحة : دراسة عشوائية متعددة المراكز
Sara Mamdouh Yousef ; Supervised Magdy Elserafy , Hany Shehab , Yasser Eltabbakh
- Cairo : Sara Mamdouh Yousef , 2021
- 64 P. : charts , facsimiles ; 25cm
Thesis (Ph.D.) - Cairo University - Faculty of Medicine - Department of Tropical Medicine
The ause of plastic stents in treatment of Post cholecystectomy CBD stricture has been shown to be effective ,now adaya metallic stents had replaced it.purpose and methodology:twenty one patients diagnosed with post cholecystectomy CBD stricture were included in ou study ,10 patients underwent ERCP with metallic stenting and 11 patients underwent multiple plastic STENTING(Mps) stenting.Results;resotion was achieved in 90% of patients in metallic group with less recurrence of post cholecystectomy CBD stricture than in MPS ,less incidence of stent migration ,number of ERCP sessions and number of stents
MPS Mtallic stent (kaffes stent) Post cholecystectomy CBD stricture