TY - BOOK AU - Heidi Yosri Mohammad Hosni Ibrahim AU - Walid Abdellatif Attia , TI - Seismic resilience quantification of a hospital designed according to ECP-201 / PY - 2021/// CY - Cairo : PB - Heidi Yosri Mohammad Hosni Ibrahim , KW - Assessment KW - Resilience KW - Seismic N1 - Thesis (M.Sc.) - Cairo University - Faculty of Engineering - Department of Civil Engineering; Issued also as CD N2 - This thesis presents seismic resilience quantification of a hospital designed according to the Egyptian code (ECP-201) in terms of repair cost, repair time and casualties. The prototype building is an existed typical 5-story reinforced concrete structure with shear walls and expansion joint, located in Suez. Building{u2019}s safety against lateral loads was checked according to ECP-201 provisions.Static non-linear (Pushover) analysis was conducted. Collapse fragility functions of building{u2019}s structural and non-structural components were established using incremental dynamic analysis (IDA). Building{u2019}s seismic resilience was quantified using new-generation seismic performance assessment methodology proposed by Federal Emergency Management Agency (FEMA), FEMA P-58 along with its associated software, Performance Assessment Calculation Tool (PACT). The outcomes show that building{u2019}s median repair time is 22 days, median repair cost is $20,850,000 which is 66.5% of the building{u2019}s total replacement cost, and median number of causalities is 386 persons UR - http://172.23.153.220/th.pdf ER -