TY - BOOK AU - Heba Allah Ibrahim Abdelrehim AU - Ahmad Wafiq Abdelmohsen , AU - Mai Mohamed Kamal Fouad , TI - Optimization of resources consumption for cleaning in place of (CIP UNITS) in dairy plants / PY - 2021/// CY - Cairo : PB - Heba Allah Ibrahim Abdelrehim , KW - CIP system group KW - CIP System KW - Optimization of CIP Unit KW - Water & energy consumption N1 - Thesis (M.Sc.) - Cairo University - Faculty of Engineering - Department of Chemical Engineering; Issued also as CD N2 - The goal of the present thesis is the optimization of water and energy consumption, in Clean-In-Place (CIP) units in dairy plants, without reduction of the cleanliness level. This was done by studying the different parameters that control the cleaning process namely, temperature and time.The deposits formed on the inside surface of the equipment as the result of the production processes are removed, during the rinsing process, by cleaning detergents.The degree of cleanliness was tested by measuring protein concentration, conductivity, pH value and swab test, where the latter was used to test for the existence of bacteria.The results showed that it is possible to decrease the water rinse time by100 seconds/cycle and the temperature by 10 or 15 degrees for some products without negatively affecting cleanliness level, resulting in water and energy savings UR - http://172.23.153.220/th.pdf ER -