Assessment of Optical Coherence Tomography changes in myopic glaucoma patients / Alia Mohammad Noureldine ; Supervised Pakinam Hashem Fouad , Heba Magdy Ahmed , Mohamed Mahmoud Khafagy

By: Contributor(s): Material type: TextTextLanguage: English Publication details: Cairo : Alia Mohammad Noureldine , 2017Description: 120 P. : charts , facsimiles ; 25cmOther title:
  • تقييم تغييرات الماسح الضوئي القطعي التوافقي في مرضي الجلوكوما قصار النظر [Added title page title]
Subject(s): Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (Ph.D.) - Cairo University - Faculty of Medicine - Department of Ophthalmology Summary: Introduction: This study{u2019}s aim was to assess the changes occurring in the OCT parameters in myopic glaucoma patients, to enable early diagnosis and thus adequate treatment and prevention of progressive glaucomatous damage. It was performed at the department of ophthalmology, Kasr Alainy Hospital, Cairo University, in a twenty months{u2019} period. Methods: This study was a cross sectional randomized single blinded study . It included 62 eyes high myopic individuals, divided into 2 groups. Patients were divided into 2 groups: Group A included myopic non glaucomatous individuals, and Group B included the myopic glaucoma patients. All patients had a full ophthalmological examination, and had an OCT assessment of the RNFL, GCC and ONH parameters. VF was tested as well as AXL and CCC. Correlation of all these data was done. Results: Regarding the Global loss volume (GLV), its mean in group A was 11.88±6.71% versus 19.69±9.69 % in group B, the difference between both groups was statistically significant (p=0.001). Regarding the cup area, the mean in group A was 0.51±0.41 mm2, while in group B was 1.25±0.72 mm2, the difference between both groups was statistically significant (p<0.001). Conclusion: The ONH parameter Cup area, and the GCC parameter GLV are key parameters in supporting the diagnosis of glaucoma in myopic patients. Other parameters measured by OCT such as inferior RNFL thickness, FLV, and C/D ratio could help in aiding the diagnosis as well
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Copy number Status Date due Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.11.24.Ph.D.2017.Al.A (Browse shelf(Opens below)) Not for loan 01010110073848000
CD - Rom CD - Rom مخـــزن الرســائل الجـــامعية - البدروم المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.11.24.Ph.D.2017.Al.A (Browse shelf(Opens below)) 73848.CD Not for loan 01020110073848000

Thesis (Ph.D.) - Cairo University - Faculty of Medicine - Department of Ophthalmology

Introduction: This study{u2019}s aim was to assess the changes occurring in the OCT parameters in myopic glaucoma patients, to enable early diagnosis and thus adequate treatment and prevention of progressive glaucomatous damage. It was performed at the department of ophthalmology, Kasr Alainy Hospital, Cairo University, in a twenty months{u2019} period. Methods: This study was a cross sectional randomized single blinded study . It included 62 eyes high myopic individuals, divided into 2 groups. Patients were divided into 2 groups: Group A included myopic non glaucomatous individuals, and Group B included the myopic glaucoma patients. All patients had a full ophthalmological examination, and had an OCT assessment of the RNFL, GCC and ONH parameters. VF was tested as well as AXL and CCC. Correlation of all these data was done. Results: Regarding the Global loss volume (GLV), its mean in group A was 11.88±6.71% versus 19.69±9.69 % in group B, the difference between both groups was statistically significant (p=0.001). Regarding the cup area, the mean in group A was 0.51±0.41 mm2, while in group B was 1.25±0.72 mm2, the difference between both groups was statistically significant (p<0.001). Conclusion: The ONH parameter Cup area, and the GCC parameter GLV are key parameters in supporting the diagnosis of glaucoma in myopic patients. Other parameters measured by OCT such as inferior RNFL thickness, FLV, and C/D ratio could help in aiding the diagnosis as well