header
Local cover image
Local cover image
Image from OpenLibrary

Comparative study between accuracy of three dimensional saline infusion sonohysterography (3DSIS) and diagnostic hysteroscopy in the diagnosis and grading of uterine fibroids in patients with menorrhagia / Reham Hany Mohamed Elkhalifa ; Supervised Ahmed Ibrahim Ahmed Aref , Wafaa Ramadan Abdelrazik Dessouky , Dalia Farouk Abdelazim

By: Contributor(s): Material type: TextTextLanguage: English Publication details: Cairo : Reham Hany Mohamed Elkhalifa , 2019Description: 107 P. : charts , facsimiles ; 25cmOther title:
  • دراسة مقارنة بين دقة الموجات الصوتية ثلا ثية الأبعاد باستخدام المحلول الملحي لتصوير التجويف الرحمي و المنظار الرحمى التشخيصى فى تشخيص و تدريج الأورام الليفية الرحمية في المرضى غزيرى الطمث [Added title page title]
Subject(s): Online resources: Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (M.Sc.) - Cairo University - Faculty of Medicine - Department of Gynecology and Obstetrics Summary: Objective: To compare the accuracy of 3D SIS and office Hysteroscopy in classification of submucous myoma in patient with menorrhagia before surgery. Methods: 50 patients with menorrhagia were recruited from our outpatient gynaecological clinic in Kasr AlAiny Training Hospital, Cairo university. All patients were diagnosed on non-enhanced two-dimensional ultrasonography with submucous fibroids. Then undergone 3D SIS using a sterile Cuscoe speculum, A 3.3{u2009}mm soft plastic paediatric naso-gastric suction catheter was then passed through the cervix into the uterine cavity without grasping the cervix. A 5{u2009}MHz transvaginal 3D ultrasound probe inserted into the vagina (Voluson 730; KretzTechnik, Austria). A volume of 5{u2013}10{u2009}ml of sterile saline solution was then instilled into the uterine cavity. A 3D volume was generated by the automatic sweep of the mechanical transducer. Then the patient undergone office hysteroscopy using a rigid 30{u00B0} hysteroscope and a 5{u2009}mm diameter diagnostic sheath (Storz Endoscopy, Germany) by an experienced operator who was blinded to the ultrasound findings. Normal saline was used to distend the uterine cavity. Infusion pressure was elevated by a pneumatic cuff under manometric control at a pressure of 100{u2013}120{u2009}mmHg
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Copy number Status Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.11.15.M.Sc.2019.Re.C (Browse shelf(Opens below)) Not for loan 01010110079108000
CD - Rom CD - Rom مخـــزن الرســائل الجـــامعية - البدروم المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.11.15.M.Sc.2019.Re.C (Browse shelf(Opens below)) 79108.CD Not for loan 01020110079108000

Thesis (M.Sc.) - Cairo University - Faculty of Medicine - Department of Gynecology and Obstetrics

Objective: To compare the accuracy of 3D SIS and office Hysteroscopy in classification of submucous myoma in patient with menorrhagia before surgery. Methods: 50 patients with menorrhagia were recruited from our outpatient gynaecological clinic in Kasr AlAiny Training Hospital, Cairo university. All patients were diagnosed on non-enhanced two-dimensional ultrasonography with submucous fibroids. Then undergone 3D SIS using a sterile Cuscoe speculum, A 3.3{u2009}mm soft plastic paediatric naso-gastric suction catheter was then passed through the cervix into the uterine cavity without grasping the cervix. A 5{u2009}MHz transvaginal 3D ultrasound probe inserted into the vagina (Voluson 730; KretzTechnik, Austria). A volume of 5{u2013}10{u2009}ml of sterile saline solution was then instilled into the uterine cavity. A 3D volume was generated by the automatic sweep of the mechanical transducer. Then the patient undergone office hysteroscopy using a rigid 30{u00B0} hysteroscope and a 5{u2009}mm diameter diagnostic sheath (Storz Endoscopy, Germany) by an experienced operator who was blinded to the ultrasound findings. Normal saline was used to distend the uterine cavity. Infusion pressure was elevated by a pneumatic cuff under manometric control at a pressure of 100{u2013}120{u2009}mmHg

Issued also as CD

There are no comments on this title.

to post a comment.

Click on an image to view it in the image viewer

Local cover image