Accuracy of sequential blood pressure measurements In comparison to ambulatory blood pressure measurements / Ayah Moustafa Elaroussy ; Supervised Yasser Mohamed Baghdady , Heba Moustafa Eldeeb , Kareem Mahmoud Abdelhamid

By: Contributor(s): Material type: TextTextLanguage: English Publication details: Cairo : Ayah Moustafa Elaroussy , 2017Description: 91 P. : charts , facsimiles ; 25cmOther title:
  • مقارنة دقة القياس التتابعي بالقياس المتنقل لضغط الدم [Added title page title]
Subject(s): Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (M.Sc.) - Cairo University - Faculty of Medicine - Department of Cardiology Summary: Background: Hypertension (HTN) is a major risk factor for cardiovascular morbidity and mortality and therefor, its diagnosis and follow up by the different methods of BP measurements are held to get the most accurate values of BP for each patient. Purpose: to compare the accuracy and degree of agreement of the automated sequential blood pressure(aSqBP)with the office blood pressure (OBP) and the ambulatory blood pressure (ABPM) readings, and whether the ABPM can replace the day-time ABPM. Methods:This cross sectionalobservational study enrolled 64 patients ,known hypertensive or to check up their BP, coming to Kasr ElAiniSpecialized hypertension clinic. Full medical history was taken. Full clinical examination, ECG and laboratory for kidney functions, were done for each patient. Blood pressure of the patient was recorded in Office BP, aSqBP and ABPM. Results: The patients age ranged between 20 and 85 years, with a mean± SD age of 50.0 ± 15.0 years.There were 53.1% females.The OBP readings were higher than the daytime ABPM asthere was a statistically significant difference between OBP and ABPM daytime SBP (mean ±SD was142.7± 15.5 versus 135.8± 15.7 mmHg, p< 0.0001), and daytimeDBP (mean ±SD was 88.5±12.3 versus 82.1± 13.7 mmHg, P <0.0001).The aSqBP has a strong positive correlation with daytime ABPM asr= 0.74 and P<0.0001.There is a moderate degree of agreement between aSqSBP anddaytime systolic ABPM and a fair degree of agreement between aSqBP and the daytime ABPM. Conclusion:The aSqBP measurement is more accurate than office BP measurement , however it can reflect the daytime ABPM moderately for the SBP& fairlyfor the DBP. ABPM is better than both of them, and is still the reference in cases with labile HTN, white coat HTN and marked BP variability
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Copy number Status Date due Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.11.04.M.Sc.2017.Ay.A (Browse shelf(Opens below)) Not for loan 01010110074521000
CD - Rom CD - Rom مخـــزن الرســائل الجـــامعية - البدروم المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.11.04.M.Sc.2017.Ay.A (Browse shelf(Opens below)) 74521.CD Not for loan 01020110074521000

Thesis (M.Sc.) - Cairo University - Faculty of Medicine - Department of Cardiology

Background: Hypertension (HTN) is a major risk factor for cardiovascular morbidity and mortality and therefor, its diagnosis and follow up by the different methods of BP measurements are held to get the most accurate values of BP for each patient. Purpose: to compare the accuracy and degree of agreement of the automated sequential blood pressure(aSqBP)with the office blood pressure (OBP) and the ambulatory blood pressure (ABPM) readings, and whether the ABPM can replace the day-time ABPM. Methods:This cross sectionalobservational study enrolled 64 patients ,known hypertensive or to check up their BP, coming to Kasr ElAiniSpecialized hypertension clinic. Full medical history was taken. Full clinical examination, ECG and laboratory for kidney functions, were done for each patient. Blood pressure of the patient was recorded in Office BP, aSqBP and ABPM. Results: The patients age ranged between 20 and 85 years, with a mean± SD age of 50.0 ± 15.0 years.There were 53.1% females.The OBP readings were higher than the daytime ABPM asthere was a statistically significant difference between OBP and ABPM daytime SBP (mean ±SD was142.7± 15.5 versus 135.8± 15.7 mmHg, p< 0.0001), and daytimeDBP (mean ±SD was 88.5±12.3 versus 82.1± 13.7 mmHg, P <0.0001).The aSqBP has a strong positive correlation with daytime ABPM asr= 0.74 and P<0.0001.There is a moderate degree of agreement between aSqSBP anddaytime systolic ABPM and a fair degree of agreement between aSqBP and the daytime ABPM. Conclusion:The aSqBP measurement is more accurate than office BP measurement , however it can reflect the daytime ABPM moderately for the SBP& fairlyfor the DBP. ABPM is better than both of them, and is still the reference in cases with labile HTN, white coat HTN and marked BP variability

Issued also as CD

There are no comments on this title.

to post a comment.