header
Image from OpenLibrary

Management of high energy proximal tibial fractures by Ilizarov external fixator / Khaled Mohammed Abdelmooty Elsisy ; Supervised Hazem Abdelazeem , Ahmed Nabawy Morrah , Mohamed Mahmoud Hegazy

By: Contributor(s): Material type: TextTextLanguage: English Publication details: Cairo : Khaled Mohammed Abdelmooty Elsisy , 2016Description: 171 P. : charts , facsimiles ; 25cmOther title:
  • علاج الكسور الناتجة عن الاصابات البالغة لأعلى عظمة القصبة بواسطة جهاز المثبت الخارجى اليزاروف [Added title page title]
Subject(s): Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (Ph.D.) - Cairo University - Faculty of Medicine - Department of Orthopaedic Surgery Summary: Background: Despite the evolution of surgical techniques and implants, high energy proximal tibia fractures remain a challenging problem. The goals of treatment are to obtain a well-aligned stable joint with a painless functional range of motion and prevention of posttraumatic arthritis. Indirect reduction techniques and other soft tissue preservation methods safeguard the vascularity and emphasize restoring both joint congruity and the mechanical axis of the limb. Aim of the work: is to evaluate the use of circular hybrid Ilizarov external fixator with or without minimal internal fixation in the management of high energy proximal tibial fractures. Methods: between March 2011 and March 2013 we treated 30 patients with high energy proximal tibia fractures including extra- and intra- articular fractures using the Ilizarov fixator, all patients were a result of high energy trauma. There were 23 male patients and 7 female patients, 14 were Right side while 16 were Left side, mean age was 36.2 years, there were 17 cases with open fractures and 13 patients had closed fractures, 21 patients had intraarticular fractures and 9 patients had extraarticular fractures. Results: all patients united in a mean time of 19 weeks, we had 9 patients with few complications that have been well treated. According to ASAMI scoring system we had excellent results in 66.7%, good results in 26.7%, fair results in 6.6% and no poor results. Conclusion: Ilizarov external fixation is a safe and effective treatment option for high energy proximal tibia fractures with good functional results
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Copy number Status Date due Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.11.25.Ph.D.2016.Kh.M (Browse shelf(Opens below)) Not for loan 01010110071847000
CD - Rom CD - Rom مخـــزن الرســائل الجـــامعية - البدروم المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.11.25.Ph.D.2016.Kh.M (Browse shelf(Opens below)) 71847.CD Not for loan 01020110071847000

Thesis (Ph.D.) - Cairo University - Faculty of Medicine - Department of Orthopaedic Surgery

Background: Despite the evolution of surgical techniques and implants, high energy proximal tibia fractures remain a challenging problem. The goals of treatment are to obtain a well-aligned stable joint with a painless functional range of motion and prevention of posttraumatic arthritis. Indirect reduction techniques and other soft tissue preservation methods safeguard the vascularity and emphasize restoring both joint congruity and the mechanical axis of the limb. Aim of the work: is to evaluate the use of circular hybrid Ilizarov external fixator with or without minimal internal fixation in the management of high energy proximal tibial fractures. Methods: between March 2011 and March 2013 we treated 30 patients with high energy proximal tibia fractures including extra- and intra- articular fractures using the Ilizarov fixator, all patients were a result of high energy trauma. There were 23 male patients and 7 female patients, 14 were Right side while 16 were Left side, mean age was 36.2 years, there were 17 cases with open fractures and 13 patients had closed fractures, 21 patients had intraarticular fractures and 9 patients had extraarticular fractures. Results: all patients united in a mean time of 19 weeks, we had 9 patients with few complications that have been well treated. According to ASAMI scoring system we had excellent results in 66.7%, good results in 26.7%, fair results in 6.6% and no poor results. Conclusion: Ilizarov external fixation is a safe and effective treatment option for high energy proximal tibia fractures with good functional results

Issued also as CD

There are no comments on this title.

to post a comment.