header
Image from OpenLibrary

Temporary hemiepiphysiodesis for correction of angular deformities around the knee using reconstruction plate / Mohamed Abdelfattah Attia Mohamed Elkak ; Supervised Sherif Mamdouh Amr , Ali Mohammad Reda Mansour , Wesam Gamal Abou Senna

By: Contributor(s): Material type: TextTextLanguage: English Publication details: Cairo : Mohamed Abdelfattah Attia Mohamed Elkak , 2016Description: 150 P. : charts , facsimiles ; 25cmOther title:
  • التثبيت المؤقت لنصف الكردوس العظمى لاصلاح التشوهات حول الركبة باستخدام شريحة اعادة بناء [Added title page title]
Subject(s): Online resources: Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (Ph.D.) - Cairo University - Faculty of Medicine - Department of Orthopaedic Surgery Summary: Background: Although osetoetomy was considered the gold standard of treatment for pathologic cases of knee deformities; it is associated with many complications. Hemiephyphiodesis using the 8-plate is a simple procedure with less morbidity, but its high cost restricts the use in developing countries. Reconstruction plate can be used instead of the 8 plate applying the same principles. Methods: This is a case series evaluating the efficacy and safety of using 3.5 mm Reconstruction plate in temporary hemiepiphysiodesis for correction of knee deformities. 15 patients with 20 deformed limbs were evaluated prospectively. Results: The mean age of cases at time of presentation was 8.7±3.3 years. The mean time of follow up was 15.9±4.5 months. The mean gain of correction was 7.6{u00B0} of mLDFA for 15.9 months and 10.2{u00B0} of MPTA for the same duration. 17 cases out of 20 were corrected (85%), 3 cases of 20 were partially corrected (15%). 2 cases developed wound infection (10%). 1 implant out of 26 was failed and needed revision (3.8%). Conclusions: Reconstruction plates are effective and safe in correcting the deformities with the advantage of being much cheaper and more widely available. By this way osteotomy had been avoided in 85% of cases
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Copy number Status Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.11.25.Ph.D.2016.Mo.T (Browse shelf(Opens below)) Not for loan 01010110071945000
CD - Rom CD - Rom مخـــزن الرســائل الجـــامعية - البدروم المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.11.25.Ph.D.2016.Mo.T (Browse shelf(Opens below)) 71945.CD Not for loan 01020110071945000

Thesis (Ph.D.) - Cairo University - Faculty of Medicine - Department of Orthopaedic Surgery

Background: Although osetoetomy was considered the gold standard of treatment for pathologic cases of knee deformities; it is associated with many complications. Hemiephyphiodesis using the 8-plate is a simple procedure with less morbidity, but its high cost restricts the use in developing countries. Reconstruction plate can be used instead of the 8 plate applying the same principles. Methods: This is a case series evaluating the efficacy and safety of using 3.5 mm Reconstruction plate in temporary hemiepiphysiodesis for correction of knee deformities. 15 patients with 20 deformed limbs were evaluated prospectively. Results: The mean age of cases at time of presentation was 8.7±3.3 years. The mean time of follow up was 15.9±4.5 months. The mean gain of correction was 7.6{u00B0} of mLDFA for 15.9 months and 10.2{u00B0} of MPTA for the same duration. 17 cases out of 20 were corrected (85%), 3 cases of 20 were partially corrected (15%). 2 cases developed wound infection (10%). 1 implant out of 26 was failed and needed revision (3.8%). Conclusions: Reconstruction plates are effective and safe in correcting the deformities with the advantage of being much cheaper and more widely available. By this way osteotomy had been avoided in 85% of cases

Issued also as CD

There are no comments on this title.

to post a comment.