Optimal dg allocation based on simple payback period by covid-19 optimizations And a modified mutation operator for grey wolf / by Mohamed Ali Hassan AbouBakr ; Under the Supervision of Dr. Mahmoud Mohamed Sayed, Dr. Tarek Abdelbadea Boghdady

By: Contributor(s): Material type: TextTextLanguage: English Summary language: English, Arabic Producer: 2023Description: 52 pages : illustrations ; 30 cm. + CDContent type:
  • text
Media type:
  • Unmediated
Carrier type:
  • volume
Other title:
  • التخصص الأمثل للوحدات الموزعة المبنية على فترة الاسترداد البسيطة باستخدام خوارزم كوفيد 19 وخوارزم الذئب الرمادي ذى معامل طفرة معدل [Added title page title]
Subject(s): DDC classification:
  • 621.3121
Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (M.Sc.)-Cairo University, 2023. Summary: Distributed Generation refers to small generating units connected to the Distribution System (DS) near the consumers (DG). The future of power production in electric networks may be bright. In recent years, there has been a noticeable increase in the demand for DG in electrical networks. The goal of distributed generation systems (DGs) is to improve the operation of the distribution system so that the advantages of adding DGs into the DS can be better understood in the power industry. If the size and location of the DGs are chosen right, such advantages can be attained. This thesis examines how adding DG units to the DS affects voltage variation, reactive power loss, and transmission efficiency in addition to from an economic standpoint. To identify the optimal answer to the distributed generation penetration problem in the DS, Grey Wolf Optimizer (GWO) is created. The output of GWO is compared to that of COVID-19 optimization, Grey Wolf Optimizer with Gaussian equation, and Grey Wolf Optimizer with Cauchy equation. MATLAB software was used to evaluate the proposed solutions' methodology on the IEEE 33 standard bus systemSummary: في هذه الرسالة ، تم دراسة مقترح مطور لإختيار أفضل سعة ومكان لوحدات التوليد الموزعة الفرعية لزيادة المنافع الاقتصادية مع الأخذ في الإعتبار معاملي الفائدة والتضخم وتحسين كفاءة نقل الطاقة ومعالجة انحراف فرق الجهد عن القيم المقننة. وحدات التوليد الموزعة الفرعية هي وحدات تتصل بشبكة التوزيع بالقرب من المستهلك وذات سعة صغيرة. تم اجراء هذا المقترح عند اضافة عدد وحدة واحدة ووحدتين وثلاث وحدات من وحدات التوليد الموزعة الفرعية. الهدف من هذه الرسالة هو تقديم دراسة كاملة لتأثير توصيل وحدات التوليد الموزعة علي الشبكة من وجهة نظر اقتصادية ووجهة نظر كفاءة النقل بعيدا عن المنظور الاقتصادي والمقارنة بينهم. وذلك باستخدام برنامج الماتلاب والمقارنة بين الخوارزميات المختلفة مثل الخوارزميات الجينية وخوارزم الحوت الأبيض وخوارزم عناصر الأسراب الجزيئية وخوارزم الذئب الرمادي للوصول للاختيار الأمثل للسعة والمكان لهذه الوحدات. في البداية تم دراسة تأثير توصيل وحدات التوليد الموزعة بشبكة التوزيع علي تعظيم كفاءة نقل الطاقة الكهربية كهدف واحد وذلك بتحديد المكان فقط وأيضا بتحديد السعة فقط وبتحديد المكان والسعة للاختيار الأمثل للسعة والمكان لهذه الوحدات. ثم دراسة تأثير توصيل هذه الوحدات بشبكه التوزيع علي تعظيم كفاءة نقل الطاقة الكهربية ومعالجه انحراف فرق الجهد عن القيم المقننة وخفض القدرة الكهربية الغير فعالة كأهداف متعددة للاختيار الأمثل للسعة والمكان لهذه الوحدات. بعد ذلك تم دراسة تأثير توصيل وحدات التوليد الموزعة بشبكة التوزيع لزيادة المنافع الاقتصادية مع الأخذ في الاعتبار معاملي الفائدة والتضخم. كما تمت الإشارة إلي الافتراضات التي أخذت في الاعتبار في هذه الرسالة لحساب التكلفة الاقتصادية اللازمة لوضع الوحدات بالسعة و المكان الأمثل تم تقسيم الرسالة إلي خمسة فصول بالإضافة إلي المراجع والملاحق وهذه الفصول سيتم تقديم ما تتناوله باختصار
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Status Date due Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.13.07.M.Sc.2023.Mo.O (Browse shelf(Opens below)) Not for loan 01010110089087000

Thesis (M.Sc.)-Cairo University, 2023.

Bibliography: pages 46-50.

Distributed Generation refers to small generating units connected to the
Distribution System (DS) near the consumers (DG). The future of power production in
electric networks may be bright. In recent years, there has been a noticeable increase in
the demand for DG in electrical networks.
The goal of distributed generation systems (DGs) is to improve the operation of
the distribution system so that the advantages of adding DGs into the DS can be better
understood in the power industry. If the size and location of the DGs are chosen right,
such advantages can be attained.
This thesis examines how adding DG units to the DS affects voltage variation,
reactive power loss, and transmission efficiency in addition to from an economic
standpoint.
To identify the optimal answer to the distributed generation penetration problem
in the DS, Grey Wolf Optimizer (GWO) is created. The output of GWO is compared to
that of COVID-19 optimization, Grey Wolf Optimizer with Gaussian equation, and
Grey Wolf Optimizer with Cauchy equation. MATLAB software was used to evaluate
the proposed solutions' methodology on the IEEE 33 standard bus system

في هذه الرسالة ، تم دراسة مقترح مطور لإختيار أفضل سعة ومكان لوحدات التوليد الموزعة الفرعية لزيادة المنافع الاقتصادية مع الأخذ في الإعتبار معاملي الفائدة والتضخم وتحسين كفاءة نقل الطاقة ومعالجة انحراف فرق الجهد عن القيم المقننة. وحدات التوليد الموزعة الفرعية هي وحدات تتصل بشبكة التوزيع بالقرب من المستهلك وذات سعة صغيرة. تم اجراء هذا المقترح عند اضافة عدد وحدة واحدة ووحدتين وثلاث وحدات من وحدات التوليد الموزعة الفرعية.
الهدف من هذه الرسالة هو تقديم دراسة كاملة لتأثير توصيل وحدات التوليد الموزعة علي الشبكة من وجهة نظر اقتصادية ووجهة نظر كفاءة النقل بعيدا عن المنظور الاقتصادي والمقارنة بينهم. وذلك باستخدام برنامج الماتلاب والمقارنة بين الخوارزميات المختلفة مثل الخوارزميات الجينية وخوارزم الحوت الأبيض وخوارزم عناصر الأسراب الجزيئية وخوارزم الذئب الرمادي للوصول للاختيار الأمثل للسعة والمكان لهذه الوحدات.
في البداية تم دراسة تأثير توصيل وحدات التوليد الموزعة بشبكة التوزيع علي تعظيم كفاءة نقل الطاقة الكهربية كهدف واحد وذلك بتحديد المكان فقط وأيضا بتحديد السعة فقط وبتحديد المكان والسعة للاختيار الأمثل للسعة والمكان لهذه الوحدات. ثم دراسة تأثير توصيل هذه الوحدات بشبكه التوزيع علي تعظيم كفاءة نقل الطاقة الكهربية ومعالجه انحراف فرق الجهد عن القيم المقننة وخفض القدرة الكهربية الغير فعالة كأهداف متعددة للاختيار الأمثل للسعة والمكان لهذه الوحدات.
بعد ذلك تم دراسة تأثير توصيل وحدات التوليد الموزعة بشبكة التوزيع لزيادة المنافع الاقتصادية مع الأخذ في الاعتبار معاملي الفائدة والتضخم. كما تمت الإشارة إلي الافتراضات التي أخذت في الاعتبار في هذه الرسالة لحساب التكلفة الاقتصادية اللازمة لوضع الوحدات بالسعة و المكان الأمثل
تم تقسيم الرسالة إلي خمسة فصول بالإضافة إلي المراجع والملاحق وهذه الفصول سيتم
تقديم ما تتناوله باختصار

Issued also as CD

Text in English and abstract in Arabic & English.