header
Image from OpenLibrary

Experimental post buckling behavior of composite battened steel columns using eps concrete subjected to axial loading / Mostafa Samy Mohamed ; Supervised Maheeb Abdelghaffar

By: Contributor(s): Material type: TextTextLanguage: English Publication details: Cairo : Mostafa Samy Mohamed , 2016Description: 89 P. : charts , facsimiles ; 30cmOther title:
  • دراسة معملية لسلوك االعمدة المركبة من الحديد وخرسانة الفوم والمعرضة لأحمال رأسية حتى الإنھيار [Added title page title]
Subject(s): Online resources: Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (M.Sc.) - Cairo University - Faculty of Engineering- Department of Civil Engineering Summary: This research work is based on strengthening the battened steel columns using light weight concrete as a filling material, and making a comparison between failure load for battened steel columns as a steel only and as a composite columns, to detect the effect of using the light weight filling material in enhancing the columns resistance. Experimental tests for nine steel battened columns with full scale test (3.0 m height) have been carried out, three of these  columns were tested as a steel only, and the other six columns were tested after filling them using Expanded  polystyrene  concrete (EPS concrete), design  load  for steel  columns was calculated according to Egyptian code of practice for steel construction and  bridges. It was  found that expected  failure load for columns according to design  load  multiplied  by safety factor 1.70 is so close to test results, and the failure load for columns filled with EPS concrete is much more than failure load for columns as a steel only, and in some cases it reaches twice  of that for steel only case load, and this considered a satisfactory result
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Copy number Status Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.13.05.M.Sc.2016.Mo.E (Browse shelf(Opens below)) Not for loan 01010110069644000
CD - Rom CD - Rom مخـــزن الرســائل الجـــامعية - البدروم المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.13.05.M.Sc.2016.Mo.E (Browse shelf(Opens below)) 69644.CD Not for loan 01020110069644000

Thesis (M.Sc.) - Cairo University - Faculty of Engineering- Department of Civil Engineering

This research work is based on strengthening the battened steel columns using light weight concrete as a filling material, and making a comparison between failure load for battened steel columns as a steel only and as a composite columns, to detect the effect of using the light weight filling material in enhancing the columns resistance. Experimental tests for nine steel battened columns with full scale test (3.0 m height) have been carried out, three of these  columns were tested as a steel only, and the other six columns were tested after filling them using Expanded  polystyrene  concrete (EPS concrete), design  load  for steel  columns was calculated according to Egyptian code of practice for steel construction and  bridges. It was  found that expected  failure load for columns according to design  load  multiplied  by safety factor 1.70 is so close to test results, and the failure load for columns filled with EPS concrete is much more than failure load for columns as a steel only, and in some cases it reaches twice  of that for steel only case load, and this considered a satisfactory result

Issued also as CD

There are no comments on this title.

to post a comment.