Effect of inter-implant distance and scan body angulation on the accuracy of digital impressions obtained by intraoral scanner following all on-4 concept : An in-vitro study / By Nour EL Hoda Mahmoud Naguib El Tarabishi; Supervisors Prof. Dr./ Khaled Ahmed Abdeen Zekry, Prof. Dr./ Amr Hosny Mostafa El Khadem, Dr. Nesma Mohamed Awaad.

By: Contributor(s): Material type: TextTextLanguage: English Summary language: English, Arabic Producer: 2023Description: 142 pages : illustrations ; 25 cm. + CDContent type:
  • text
Media type:
  • Unmediated
Carrier type:
  • volume
Other title:
  • تأثير تغيير المسافة بين الغرسات و ميل هيكل المسح الرقمى على دقة الطبعات الرقمية المسجلة بالماسح الفمى فى حالات التعويض الكلى على أربع غرسات : دراسة معملية [Added title page title]
Subject(s): DDC classification:
  • 617.69
Available additional physical forms:
  • Issues also as CD.
Dissertation note: Thesis (M.Sc.)-Cairo University, 2023. Summary: This was a non- randomized in-vitro study, in which an edentulous mandibular master model was designed following the All-on-4 concept, with recesses of digital implant analogs. The analogs were located in anterior and posterior regions using computer aided design software. The master model was 3D printed by Digital Light Processing (DLP). After which, the accuracy of intraoral scanner was assessed at varied interimplant distances and distal abutment angulation.The intervention to evaluate the effect of interimplant distance on scanner accuracy were the long and short interimplant distance group. The short interimplant distance group had the most distal implant at the first premolar region. The long interimplant distance group had the most distal implant at the second premolar region instead. Both the short and long interimplant distance groups had three subgroups with varied distal multi-unit abutment angulation 0, 15, 30- degrees. Intraoral scan bodies were assembled over the multi-unit abutments for the scanning of the master model.The master model was scanned once with a reference scanner for all groups to obtain the reference scan. The intraoral scanner was used to obtain 10 test scans for each group. Accuracy measurements using Medit design app feature, were performed by superimposition of the test scans over the reference scan of each group. The deviation values of the test scans from the reference scan were used for statistical analysis. Results showed that as the interimplant distance had no effect on the accuracy. Also, an increase in the angulation negatively affected the accuracy of the intraoral scanner.Summary: كانت هذه دراسة غير عشوائية في المختبر ، حيث تم تصميم نموذج رئيسي للفك السفلي متقلبًا وفقًا لمفهوم All-on-4 ، مع فترات استراحة لنظائر الغرسات الرقمية. تم وضع النظائر في المناطق الأمامية والخلفية باستخدام برامج التصميم بمساعدة الكمبيوتر. تم طباعة النموذج الرئيسي ثلاثي الأبعاد بواسطة (DLP) المعالجة الرقمية الضوئية . بعد ذلك ، تم تقييم دقة الماسح الضوئي داخل الفم على مسافات مؤقتة متنوعة وتزويد دعامة بعيدة . كان التدخل لتقييم تأثير مسافة الزرع المؤقتة على دقة الماسح الضوئي هو مجموعة مسافة الزرع المؤقتة الطويلة والقصيرة. كانت المجموعة قصيرة المسافة المؤقتة للزراعة تمتلك الزرع الأبعد في منطقة الضواحك الأولى. كانت مجموعة الزرع الطويلة المؤقتة هي الزرع الأكثر بعدًا في منطقة الضاحك الثانية بدلاً من ذلك. تحتوي كلتا مجموعتي المسافة المؤقتة الطويلة والقصيرة على ثلاث مجموعات فرعية ذات زاوية دعامة متعددة الوحدات بعيدة ومتنوعة 0 ، 15 ، 30 درجة. تم تجميع أجسام المسح داخل الفم على دعامات متعددة الوحدات لمسح النموذج الرئيسي . تم مسح النموذج الرئيسي مرة واحدة باستخدام ماسح ضوئي مرجعي لجميع المجموعات للحصول على المسح المرجعي. تم استخدام الماسح الضوئي داخل الفم للحصول على 10 فحوصات لكل مجموعة. تم إجراء قياسات الدقة باستخدام ميزة تطبيق Medit design عن طريق تراكب فحوصات الاختبار على المسح المرجعي لكل مجموعة . تم استخدام قيم الانحراف لعمليات المسح الاختبارية من المسح المرجعي للتحليل الإحصائي. أظهرت النتائج أنه زيادت مسافة الزرع المؤقتة لم تؤثر على الدقة. أيضا ، أثرت الزيادة في الزوايا سلبًا على دقة الماسح الضوئي داخل الفم .
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Status Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.09.M.Sc.2023.No.E. (Browse shelf(Opens below)) Not for loan 01010110089952000

Thesis (M.Sc.)-Cairo University, 2023.

Bibliography: pages 127-137.

This was a non- randomized in-vitro study, in which an edentulous mandibular master model was designed following the All-on-4 concept, with recesses of digital implant analogs. The analogs were located in anterior and posterior regions using computer aided design software. The master model was 3D printed by Digital Light Processing (DLP). After which, the accuracy of intraoral scanner was assessed at varied interimplant distances and distal abutment angulation.The intervention to evaluate the effect of interimplant distance on scanner accuracy were the long and short interimplant distance group. The short interimplant distance group had the most distal implant at the first premolar region. The long interimplant distance group had the most distal implant at the second premolar region instead. Both the short and long interimplant distance groups had three subgroups with varied distal multi-unit abutment angulation 0, 15, 30- degrees. Intraoral scan bodies were assembled over the multi-unit abutments for the scanning of the master model.The master model was scanned once with a reference scanner for all groups to obtain the reference scan. The intraoral scanner was used to obtain 10 test scans for each group. Accuracy measurements using Medit design app feature, were performed by superimposition of the test scans over the reference scan of each group.
The deviation values of the test scans from the reference scan were used for statistical analysis. Results showed that as the interimplant distance had no effect on the accuracy. Also, an increase in the angulation negatively affected the accuracy of the intraoral scanner.

كانت هذه دراسة غير عشوائية في المختبر ، حيث تم تصميم نموذج رئيسي للفك السفلي متقلبًا وفقًا لمفهوم All-on-4 ، مع فترات استراحة لنظائر الغرسات الرقمية. تم وضع النظائر في المناطق الأمامية والخلفية باستخدام برامج التصميم بمساعدة الكمبيوتر. تم طباعة النموذج الرئيسي ثلاثي الأبعاد بواسطة (DLP) المعالجة الرقمية الضوئية . بعد ذلك ، تم تقييم دقة الماسح الضوئي داخل الفم على مسافات مؤقتة متنوعة وتزويد دعامة بعيدة . كان التدخل لتقييم تأثير مسافة الزرع المؤقتة على دقة الماسح الضوئي هو مجموعة مسافة الزرع المؤقتة الطويلة والقصيرة. كانت المجموعة قصيرة المسافة المؤقتة للزراعة تمتلك الزرع الأبعد في منطقة الضواحك الأولى. كانت مجموعة الزرع الطويلة المؤقتة هي الزرع الأكثر بعدًا في منطقة الضاحك الثانية بدلاً من ذلك. تحتوي كلتا مجموعتي المسافة المؤقتة الطويلة والقصيرة على ثلاث مجموعات فرعية ذات زاوية دعامة متعددة الوحدات بعيدة ومتنوعة 0 ، 15 ، 30 درجة. تم تجميع أجسام المسح داخل الفم على دعامات متعددة الوحدات لمسح النموذج الرئيسي . تم مسح النموذج الرئيسي مرة واحدة باستخدام ماسح ضوئي مرجعي لجميع المجموعات للحصول على المسح المرجعي. تم استخدام الماسح الضوئي داخل الفم للحصول على 10 فحوصات لكل مجموعة. تم إجراء قياسات الدقة باستخدام ميزة تطبيق Medit design عن طريق تراكب فحوصات الاختبار على المسح المرجعي لكل مجموعة . تم استخدام قيم الانحراف لعمليات المسح الاختبارية من المسح المرجعي للتحليل الإحصائي. أظهرت النتائج أنه زيادت مسافة الزرع المؤقتة لم تؤثر على الدقة. أيضا ، أثرت الزيادة في الزوايا سلبًا على دقة الماسح الضوئي داخل الفم .

Issues also as CD.

Text in English and abstract in English.

There are no comments on this title.

to post a comment.

Click on an image to view it in the image viewer

Local cover image