Effect of er, cr:ysgg laser surface treatment on microshear bond strength of monolithic extra translucent zirconia to resin cement : An in-vitro study / By Rana Ayman Aly Gadalla; SUPERVISORS Prof. Dr. Mohamed Labib Zamzam, Dr. Omnia Nabil Ahmed.

By: Contributor(s): Material type: TextTextLanguage: English Summary language: English, Arabic Producer: 2024Description: 83 pages : illustrations ; 25 cm. + CDContent type:
  • text
Media type:
  • Unmediated
Carrier type:
  • volume
Other title:
  • تأثير المعالجة السطحية بالليزرعلي قوة رابطة القص الدقيقة بين الزركونيا زائدة الشفافية المتكشفة عن وحدة متراصة والأسمنت الراتنجي : دراسة معملية [Added title page title]
Subject(s): DDC classification:
  • 617.695
Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (M.Sc.)-Cairo University, 2024. Summary: Aim: The aim of the study was to evaluate the effect of Er,Cr:YSGG laser surface treatment at various power settings on the microshear bond strength between extra translucent zirconia and resin cement, comparing it to the results obtained with sandblasting. Materials and methods: Thirty-six sintered Cercon xt zirconia specimens were randomly divided into four equal groups (n=9) according to the surface treatment performed: Group SB (Control): Sandblasting using 110μm alumina particles, Group 6W: Er,Cr:YSGG laser irradiation at 6W power, Group 8W: Er,Cr:YSGG laser irradiation at 8W power, and Group 10W: Er,Cr:YSGG laser irradiation at 10W power. One sample from each group was analyzed using a scanning electron microscope (SEM). Subsequently, all specimens were treated with Z-Prime Plus, and then Theracem resin cylinders were prepared and applied to the treated surfaces, followed by light curing for 20 seconds. Next, all specimens were fixed to a universal testing machine, and a microshear bond test was conducted with a cross-head speed of 1 mm/min until debonding occurred. The type of bond failures was determined using a stereomicroscope and further examined with SEM. Results: One Way ANOVA test revealed that the difference between the study groups was not statistically significant as the recorded p-value=0.91. The sandblasted samples showed noticeable micromechanical roughening and irregularities, with a predominantly mixed-type bond failure. In contrast, the laser-treated surfaces displayed considerably reduced roughness compared to those treated with sandblasting, and the failure mode was predominantly adhesive. Conclusions: Er,Cr:YSGG laser irradiation at 6W, 8W and 10W output powers can be regarded as surface treatment options for extra translucent zirconia to establish reliable bond strength with resin cement.Summary: لطالما كان الالتصاق بالزركونيا محط اهتمام على مر السنين، حيث برز التجهيز بالرمال) السفع) كطريقة عملية لمعالجة السطح، على الرغم من عيوبه المتأصلة. اكتسب التشعيع بالليزر، بما في ذلك الليزر Er,Cr:YSGG، اهتمامًا أيضًا كطريقة بديلة لمعالجة سطح سيراميك الزركونيا، مع تأثيرات على الأسطح من خلال آليات الاستئصال. الهدف من هذه الدراسة كان تقييم تأثير استخدام إعدادات طاقة مختلفة لإشعاع الليز Er,Cr:YSGG، كمعالجة سطحية، على قوة رابطة القص الدقيق للزركونيا زائدة الشفافية مع أسمنت الراتنج, ومقارنة ذلك بالنتائج التي تم الحصول عليها باستخدام السفع الرملي. تم خرط ستة وثلاثين عينة من زركونيا Cercon xt وتقسيمها عشوائيًا إلى أربع مجموعات متساوية (العدد = 9) وفقًا للمعالجة السطحية التي تم إجراؤها: المجموعةSB : السفع الرملي باستخدام جزيئات أكسيد الألومنيوم 110 ميكرومتر، المجموعة :6Wتشعيع ليزر Er,Cr:YSGG عند6W طاقة ، المجموعة :8W تشعيع ليزر Er,Cr:YSGG عند 8W طاقة ، والمجموعة :10W تشعيع ليزر Er,Cr:YSGG عند 10Wطاقة .تم تحليل عينة واحدة من كل مجموعة باستخدام المجهر الإلكتروني الماسح .(SEM) بعد المعالجات السطحية الميكانيكية، تم تطبيق Z-Prime Plus على جميع عينات الزركونيا من جميع المجموعات. بعد ذلك، تم تصنيع أنابيب الأسمنت الراتينج باستخدام قوالب بولي إيثيلين بأبعاد 1.5 مم في القطر الداخلي و2 مم في الارتفاع، مشتقة من قسطرة نيلاتون.6FG تم وضع قالب في وسط كل عينة، ثم ملؤه بـ TheraCem. ثم البلمرة لمدة 20 ثانية. بعد ذلك تم استخراج القوالب بعناية من أنابيب الراتنج الناتجة باستخدام مشرط حاد. بعد ذلك تم تثبيت جميع العينات على آلة الاختبار وتم إجراء اختبار رابطة القص الدقيق بسرعة عرضية قدرها 1 مم/دقيقة حتى حدوث عملية فك الارتباط. تم تحديد أنواع فشل السندات باستخدام مجهر مجسم وتم فحصها بشكل أكبر باستخدام. SEM أظهرت النتائج أن الفرق بين المجموعات الدراسية لم يكن ذا دلالة إحصائية حيث كانت قيمة P المسجلة 0.91. أظهرت العينات المسفوعة بالرمل خشونة مجهرية ملحوظة، مع فشل ارتباط مختلط بشكل أساسي. على النقيض من ذلك، أظهرت الأسطح المعالجة بالليزر خشونة منخفضة بشكل ملحوظ مقارنة بتلك التي عولجت بالسفع الرملي، وكان نمط الفشل لاصقًا بشكل أساسي. تم التوصل إلى أن تشعيع الليزر Er,Cr: YSGGبقدرات خرج 6 وات و8 وات و10 وات يمكن اعتباره من ضمن خيارات المعالجة السطحية للزركونيا زائدة الشفافية لإنشاء قوة ربط موثوقة مع أسمنت الراتنج.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Status Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.09.M.Sc.2024.Ra.E. (Browse shelf(Opens below)) Not for loan 01010110090649000

Thesis (M.Sc.)-Cairo University, 2024.

Bibliography: pages 74-80.

Aim: The aim of the study was to evaluate the effect of Er,Cr:YSGG laser surface treatment at various power settings on the microshear bond strength between extra translucent zirconia and resin cement, comparing it to the results obtained with sandblasting. Materials and methods: Thirty-six sintered Cercon xt zirconia specimens were randomly divided into four equal groups (n=9) according to the surface treatment performed: Group SB (Control): Sandblasting using 110μm alumina particles, Group 6W: Er,Cr:YSGG laser irradiation at 6W power, Group 8W: Er,Cr:YSGG laser irradiation at 8W power, and Group 10W: Er,Cr:YSGG laser irradiation at 10W power. One sample from each group was analyzed using a scanning electron microscope (SEM). Subsequently, all specimens were treated with Z-Prime Plus, and then Theracem resin cylinders were prepared and applied to the treated surfaces, followed by light curing for 20 seconds. Next, all specimens were fixed to a universal testing machine, and a microshear bond test was conducted with a cross-head speed of 1 mm/min until debonding occurred. The type of bond failures was determined using a stereomicroscope and further examined with SEM.
Results: One Way ANOVA test revealed that the difference between the study groups was not statistically significant as the recorded p-value=0.91. The sandblasted samples showed noticeable micromechanical roughening and irregularities, with a predominantly mixed-type bond failure. In contrast, the laser-treated surfaces displayed considerably reduced roughness compared to those treated with sandblasting, and the failure mode was predominantly adhesive. Conclusions: Er,Cr:YSGG laser irradiation at 6W, 8W and 10W output powers can be regarded as surface treatment options for extra translucent zirconia to establish reliable bond strength with resin cement.

لطالما كان الالتصاق بالزركونيا محط اهتمام على مر السنين، حيث برز التجهيز بالرمال) السفع) كطريقة عملية لمعالجة السطح، على الرغم من عيوبه المتأصلة. اكتسب التشعيع بالليزر، بما في ذلك الليزر Er,Cr:YSGG، اهتمامًا أيضًا كطريقة بديلة لمعالجة سطح سيراميك الزركونيا، مع تأثيرات على الأسطح من خلال آليات الاستئصال. الهدف من هذه الدراسة كان تقييم تأثير استخدام إعدادات طاقة مختلفة لإشعاع الليز Er,Cr:YSGG، كمعالجة سطحية، على قوة رابطة القص الدقيق للزركونيا زائدة الشفافية مع أسمنت الراتنج, ومقارنة ذلك بالنتائج التي تم الحصول عليها باستخدام السفع الرملي.
تم خرط ستة وثلاثين عينة من زركونيا Cercon xt وتقسيمها عشوائيًا إلى أربع مجموعات متساوية (العدد = 9) وفقًا للمعالجة السطحية التي تم إجراؤها: المجموعةSB : السفع الرملي باستخدام جزيئات أكسيد الألومنيوم 110 ميكرومتر، المجموعة :6Wتشعيع ليزر Er,Cr:YSGG عند6W طاقة ، المجموعة :8W تشعيع ليزر Er,Cr:YSGG عند 8W طاقة ، والمجموعة :10W تشعيع ليزر Er,Cr:YSGG عند 10Wطاقة .تم تحليل عينة واحدة من كل مجموعة باستخدام المجهر الإلكتروني الماسح .(SEM) بعد المعالجات السطحية الميكانيكية، تم تطبيق Z-Prime Plus على جميع عينات الزركونيا من جميع المجموعات. بعد ذلك، تم تصنيع أنابيب الأسمنت الراتينج باستخدام قوالب بولي إيثيلين بأبعاد 1.5 مم في القطر الداخلي و2 مم في الارتفاع، مشتقة من قسطرة نيلاتون.6FG تم وضع قالب في وسط كل عينة، ثم ملؤه بـ TheraCem. ثم البلمرة لمدة 20 ثانية. بعد ذلك تم استخراج القوالب بعناية من أنابيب الراتنج الناتجة باستخدام مشرط حاد. بعد ذلك تم تثبيت جميع العينات على آلة الاختبار وتم إجراء اختبار رابطة القص الدقيق بسرعة عرضية قدرها 1 مم/دقيقة حتى حدوث عملية فك الارتباط. تم تحديد أنواع فشل السندات باستخدام مجهر مجسم وتم فحصها بشكل أكبر باستخدام. SEM
أظهرت النتائج أن الفرق بين المجموعات الدراسية لم يكن ذا دلالة إحصائية حيث كانت قيمة P المسجلة 0.91. أظهرت العينات المسفوعة بالرمل خشونة مجهرية ملحوظة، مع فشل ارتباط مختلط بشكل أساسي. على النقيض من ذلك، أظهرت الأسطح المعالجة بالليزر خشونة منخفضة بشكل ملحوظ مقارنة بتلك التي عولجت بالسفع الرملي، وكان نمط الفشل لاصقًا بشكل أساسي. تم التوصل إلى أن تشعيع الليزر Er,Cr: YSGGبقدرات خرج 6 وات و8 وات و10 وات يمكن اعتباره من ضمن خيارات المعالجة السطحية للزركونيا زائدة الشفافية لإنشاء قوة ربط موثوقة مع أسمنت الراتنج.

Issued also as CD

Text in English and abstract in English.