header
Local cover image
Local cover image
Image from OpenLibrary

Fault detection and diagnosis in differential and / or ac coupled circuits / Hisham Gamal Mohamed Daoud ; Supervised Amin Mohamed Nassar

By: Contributor(s): Language: Eng Publication details: Cairo : Hisham Gamal Mohamed Daoud , 2007Description: 108P. : ill. ; 30CmOther title:
  • اكتشاف و تحديد اعطال فى الدوائرالتباينية والدوائرالمتصلة عبر التيار المتردد [Added title page title]
Subject(s): Online resources: Available additional physical forms:
  • Issued as also CD
Dissertation note: Thesis (M.Sc.) - Cairo University - Faculty Of Engineering - Department Of Electronics and Communications Summary: The boundary scan technique doesn{u2019}t have the ability to address the differential and AC coupled circuits due to the requirements of AC test signal and also the test signal detection based on edge detection.For that purpose , the IEEE 1149.6 standard was developed.In this work , a study of this Standard is accomplished and a case study of LVDS circuit is used to verify the efficiency of the standard from the side of fault detection and diagnosis , by applying the standard to the Circuit Under Test and analyzing the simulation results of the both fault - free and faulty cases for different kinds of faults.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Copy number Status Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.13.08.M.Sc.2007.Hi.F (Browse shelf(Opens below)) Not for loan 01010110047066000
CD - Rom CD - Rom مخـــزن الرســائل الجـــامعية - البدروم المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.13.08.M.Sc.2007.Hi.F (Browse shelf(Opens below)) 47066.CD Not for loan 01020110047066000

Thesis (M.Sc.) - Cairo University - Faculty Of Engineering - Department Of Electronics and Communications

The boundary scan technique doesn{u2019}t have the ability to address the differential and AC coupled circuits due to the requirements of AC test signal and also the test signal detection based on edge detection.For that purpose , the IEEE 1149.6 standard was developed.In this work , a study of this Standard is accomplished and a case study of LVDS circuit is used to verify the efficiency of the standard from the side of fault detection and diagnosis , by applying the standard to the Circuit Under Test and analyzing the simulation results of the both fault - free and faulty cases for different kinds of faults.

Issued as also CD

There are no comments on this title.

to post a comment.

Click on an image to view it in the image viewer

Local cover image