header
Image from OpenLibrary

Reliability of electronic digital caliper in the assessment of rectus abdominis diastasis / Asmaa Abdelhamid Moustafa ; Supervised Hala Mohamed Hanafy , Marwa Abdelrahman Mohamed , Ahmed Mohamed Reiad

By: Contributor(s): Material type: TextTextLanguage: English Publication details: Cairo : Asmaa Abdelhamid Moustafa , 2015Description: 79 P. : facsimiles ; 25cmOther title:
  • مدى دقه المقياس الالكترونى الرقمى فى تقييم تباعد عضلات البطن المستقيمه [Added title page title]
Subject(s): Online resources: Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (M.Sc.) - Cairo University - Faculty of Physical Therapy - Department of Physical Therapy for Gynecology and Obstetrics Summary: The purpose of this study was to determine the reliability of electronic digital caliper in the assessment of diastasis recti during the puerperal period. Thirty volunteer women at puerperal period after normal delivery were participated in this study. They were selected from outpatient clinics of Ain Shams university hospital. Their ages were ranged from 20 to 35 years old. All subjects were 4 to 20 weeks postpartum after normal delivery. Their parity was ranged from (1 - 3). Inter recti distance was measured at 3 locations; at umbilicus level, above umbilicus level and below umbilicus level, under 2 conditions; with abdominal muscles at rest and with abdominal muscles contracted. These measurements were tested three times with at least 5 minutes between each test trial. Results showed that electronic digital caliper measurements have perfect agreement during measuring inter recti distance (IRD) above umbilicus level at rest, at umbilicus level at rest, and below umbilicus level at rest respectively, and have strong agreement during measuring (IRD) above umbilicus level at action, and at umbilicus level at action respectively, and have moderate agreement in measuring (IRD) below umbilicus level at action
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Copy number Status Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.21.04.M.Sc.2015.As.R (Browse shelf(Opens below)) Not for loan 01010110067826000
CD - Rom CD - Rom مخـــزن الرســائل الجـــامعية - البدروم المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.21.04.M.Sc.2015.As.R (Browse shelf(Opens below)) 67826.CD Not for loan 01020110067826000

Thesis (M.Sc.) - Cairo University - Faculty of Physical Therapy - Department of Physical Therapy for Gynecology and Obstetrics

The purpose of this study was to determine the reliability of electronic digital caliper in the assessment of diastasis recti during the puerperal period. Thirty volunteer women at puerperal period after normal delivery were participated in this study. They were selected from outpatient clinics of Ain Shams university hospital. Their ages were ranged from 20 to 35 years old. All subjects were 4 to 20 weeks postpartum after normal delivery. Their parity was ranged from (1 - 3). Inter recti distance was measured at 3 locations; at umbilicus level, above umbilicus level and below umbilicus level, under 2 conditions; with abdominal muscles at rest and with abdominal muscles contracted. These measurements were tested three times with at least 5 minutes between each test trial. Results showed that electronic digital caliper measurements have perfect agreement during measuring inter recti distance (IRD) above umbilicus level at rest, at umbilicus level at rest, and below umbilicus level at rest respectively, and have strong agreement during measuring (IRD) above umbilicus level at action, and at umbilicus level at action respectively, and have moderate agreement in measuring (IRD) below umbilicus level at action

Issued also as CD

There are no comments on this title.

to post a comment.