000 08278namaa22004331i 4500
003 OSt
005 20250223033401.0
008 250102s2023 |||a|||fr|m|| 000 0 eng d
040 _aEG-GICUC
_beng
_cEG-GICUC
_dEG-GICUC
_erda
041 0 _aeng
_beng
_bara
049 _aDeposit
082 0 4 _a617.7
092 _a617.7
_221
097 _aPh.D
099 _aCai01.11.24.Ph.D.2023.Al.C
100 0 _aAlaa Mohamed Badawy Mohamed,
_epreparation.
245 1 2 _aA Comparative Study of Visual Outcome of Two Extended Depth of Focus Intraocular Lenses after Cataract Surgery /
_cby Alaa Mohamed Badawy Mohamed ; Supervised by Prof. Dr. Yehia Salah Eldin Mostafa, Prof. Mohamed Hassan Hosny, Dr. Sarah Akram Hassan Azzam.
246 1 5 _aدراسة مقارنة للنتائج البصرية عن استخدام عدستين ذات العمق البؤري الممتد التى يتم زراعتها داخل العين بعد عملية المياه البيضاء /
264 0 _c2023.
300 _a98 pages :
_billustrations ;
_c25 cm. +
_eCD.
336 _atext
_2rda content
337 _aUnmediated
_2rdamedia
338 _avolume
_2rdacarrier
502 _aThesis (Ph.D)-Cairo University, 2023.
504 _aBibliography: pages 88-98.
520 _aOver the recent years, there has been an increased demand of spectacle independence for both intermediate and near vision. Standard monofocal lenses allow the patient‘s vision to focus at only one distance (i.e. distance or near). Multiple studies demonstrated that both multifocal and EDOF IOLs provide good intermediate and near vision , however , comparative studies found that while multifocal IOLs generally have better results regarding near vision , EDOF IOLs show better results in terms of intermediate vision and contrast sensitivity. Purpose: We aimed to compare the visual performance of the extended depth of focus intraocular lens ; AcrySof™ IQ Vivity™ and the hybrid extended depth of focus intraocular lens TECNIS Synergy™ (regarding Uncorrected and corrected monocular distance and intermediate and near visual acuity and the range of vision (using defocus curve) ), contrast sensitivity (objectively through the modulation transfer function curves) and the Photic phenomena (objectively expressed through the effect on total higher ocular aberration) which were measured using the Itrace (Houston, Texas ,U.S.A.). Methods: This is a prospective comparative case series , that took place in 2 private eye centers , in the period between November 2021 to August 2023. 34 eyes of 20 patients were enrolled in this study, patients who are candidates for cataract extraction by phacoemulsification were included in this study and underwent thorough preoperative examination and post-operative evaluation at 3 months, of distance, intermediate and near visual acuity , defocus curves were analyzed. Moreover, the internal HOA and MTF were measured using the iTRACE. Results: A total of 34 eyes of 20 patients were included in this study. Monocular distance visual acuity outcomes were excellent in both study groups achieving mean UCDVA and BCDVA of 0.09 LogMAR & 0.04 LogMAR in the TECNIS Synergy™ group and 0.14 LogMAR & 0.09 LogMAR in the the AcrySof™ IQ Vivity™ with no statistically significant difference .The intermediate vision was comparable in both groups where the mean UCIVA & DCIVA were 0.12 LogMAR & 0.09 LogMAR in the TECNIS Synergy™ group and 0.14 LogMAR & 0.07 LogMAR in the AcrySof™ IQ Vivity™ group with no statistically significant difference . The near visual acuity was significantly better in the TECNIS synergy group with a mean UCNVA and DCNVA of 0.14 LogMAR &0.09 LogMAR in the TECNIS Synergy™ group and 0.33 LogMAR &0.31 LogMAR in the the AcrySof™ IQ Vivity™ group. Regarding the defocus curve , visual acuity was maintained above 0.2 LogMAR throughout the curve from distance through near in the Tecnis SYNERGY . On the other hand , in the AcrySof™ IQ Vivity™ group , the visual acuity was nearly maintained at 0.1 LogMAR in the range between 0 D and -1.00 D and a sharp decline at -2.0 D from 0.2 LogMAR to 0.4 LogMAR at -3.0 D .The mean MTF value (at frequency = 10 HZ ) was 0.42 in the TECNIS Synergy™ group and in the the AcrySof™ IQ Vivity™ group was 0.27 with a non - statistically significant difference .The mean total internal HOA was 0.32 μm in the TECNIS Synergy™ group and in the the AcrySof™ IQ Vivity™ group was 0.27 μm with a non -statistically significant difference
520 _aفائدة عملية إزالة المياه البيضاء هي استعادة حدة الإبصار كما هي بالنسبة للعدسة الطبيعية واستخدام العدسات ذات البؤرة الواحدة يمكن أن يعوض حدة الإبصار المطلوبة للمسافة البعيدة، ولكن يحتاج أن يصاحبه استخدام النظارات الطبية لتعويض حدة الإبصار للمسافة المتوسطة والقريبة، وباستخدام العدسات متعددة البؤر فإن هذه العدسات قد توفر حدة الإبصار المطلوبة للمسافة المتوسطة والقريبة، ولكن غالبا ما يصاحبه بعض الأعراض الجانبية والظواهر البصرية التي تؤثر على حساسية التباين. تتزايد انواع العدسات التي يتم زراعتها داخل العين التي تستخدم في اصلاح قصر البصر الشيخوخي من اجل التخلص من استخدام النظارة بعد عمليات المياه البيضاء . عدسة التكنس سينرجي (شركة جونسون و جونسون) هي عدسة مهجنة بين تصميم العدسات متعددة البؤرة و العدسات ممتدة ابؤرة لتتمكن من الحصول علي رؤية ممتدة و ذات تباين عالي من المسافة البعيد حتي المسافة القريبة تم طرحها حديثا في الاسواق . علي الصعيد الاخرعدسة الاكريسوف اي كيو فيفيتي هي عدسة ممتدة البؤرة و التي قد تم طرحها مؤخرا بالاسواق . و هي اول عدسة تعتمد علي تكنولوجيا الاكس ويف التي تعتمد علي امتداد الضوء و ليس تشتيته . الغرض من الرسالة : اجراء دراسة مقارنة للنتايج البصرية لكل من العدستين السينرجي و الفيفتي من حيث حدة الابصار علي مسافات (البعيدة و المتوسطة و القريبة) و قياس مدي الرؤية عن طريق القيام برسم انحاء اللا تبأورو `حساسية التباين و تقييم الظواهر البصرية المصاحبة بطريقة موضوعية عن طريق قياسهم بجاز الاي تريس . طرق البحث : متابعة 34 عين و 17 منهم قام بزراعة الفيفتي و 17 منهم قام بزراعة السينرجي . ملخص النتائج : حدة الإبصار البعيدة و المتوسطة كانت متماثلة احصائيا بالنسبة للعدستين بينما كانت العدسة السينرجي أفضل من حيث حدة الإبصارالقريبة وكانت حساسية التباين متماثلة احصائيا بالنسبة للعدستين و كذلك الظواهر البصرية المصاحبة
530 _aIssued also as CD
546 _aText in English and abstract in Arabic & English.
650 7 _aOphthalmology
_2qrmak
653 0 _aTECNIS Synergy
_aAcrysof IQ Vivity
_adefocus curve
_aintermediate vision
_anear vision
_ahigher order aberration & MTF
700 0 _aYehia Salah Eldin Mostafa
_ethesis advisor.
700 0 _aMohamed Hassan Hosny
_ethesis advisor.
700 0 _aSarah Akram Hassan Azzam
_ethesis advisor.
900 _b01-01-2023
_cYehia Salah Eldin Mostafa
_cMohamed Hassan Hosny
_cSarah Akram Hassan Azzam
_dShiref Ali
_dTamer Mohamed
_UCairo University
_FFaculty of Medicine
_DDepartment of Ophthalmology
905 _aEman
_eHuda
942 _2ddc
_cTH
_e21
_n0
999 _c169948