245 1 0 _aShaping ability, centering ability and cutting efficiency in curved root canals using S5 endo files versus a regular system :
_bAn in vitro study /
_cMohammed Ahmed Omar AbouElseoud ; Supervised Medhat AboElrahman H. Kataia , Samia Mohammed Elsherif
246 1 5 _aتشكيل القدرة: و تتركز قدرة و كفاءة في قطع قنوات الجذر منحني باستخدام أس فايف إندو الروتاري في مقابل نظام الملفات العادية
260 _aCairo :
_bMohammed Ahmed Omar AbouElseoud ,
_c2010
300 _a123 Leaves :
_bphotographs ;
_c30cm
502 _aThesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Endodontics
520 _aThe aim of the study was to compare between two rotary instruments S5 files and Universal Pro Taper in terms of shaping, Centering and Cutting abilities. Sixty mandibular and maxillary mesio-buccal roots were used, in part 1: test for shaping ability in terms of maintaining root canal curvature with curvature ranging from 20{u00BA} to 67{u00BA} , 20 mesio-buccal mandibular molars were used degree of canal curvature and location of the curvature were done by hulsmann and stryga a slight modification of schneider's technique and by Berbert and Nishlyama respectively
530 _aIssued also as CD
653 4 _aCurved root canals
653 4 _aRegular system
653 4 _aS5 endo files
700 0 _aMedhat Abdelrahman Hassan Kataia ,
_eSupervisor
700 0 _aSamia Mohammed Elsherif ,
_eSupervisor
856 _uhttp://172.23.153.220/th.pdf
905 _aNazla
_eRevisor
905 _aSamia
_eCataloger
942 _2ddc
_cTH
999 _c37728
_d37728