000 | 02639cam a2200349 a 4500 | ||
---|---|---|---|
003 | EG-GiCUC | ||
005 | 20250223031422.0 | ||
008 | 160203s2015 ua dh f m 000 0 eng d | ||
040 |
_aEG-GiCUC _beng _cEG-GiCUC |
||
041 | 0 | _aeng | |
049 | _aDeposite | ||
097 | _aPh.D | ||
099 | _aCai01.09.13.Ph.D.2015.Es.C | ||
100 | 0 | _aEssam Ahmed Mohammed Almoraissi | |
245 | 1 | 0 |
_aComparison between three-dimensional and standard miniplates in the fixation of mandibular angle fractures : _bRandomized, controlled clinical trial / _cEssam Ahmed Mohammed Almoraissi ; Supervised Ragia M. Mounair , Tarek Elsharkawy , Tarek Elghareeb |
246 | 1 | 5 |
_aمقارنه بين الشرائح ثلاثية الابعاد و القياسية فى تثبيت الكسور لزاوية الفك السفلى : _bدراسة مقارنه عشوائية سريرية |
260 |
_aCairo : _bEssam Ahmed Mohammed Almoraissi , _c2015 |
||
300 |
_a154 P. : _bcharts , facsimiles ; _c25cm |
||
502 | _aThesis (Ph.D.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Oral and Maxillofacial Surgery | ||
520 | _aThe aim of this study was to compare the clinical and radiological outcomes of mandibular angle fractures (MAFs) managed with three-dimensional (3D) miniplates and standard miniplates (according to champy{u2019}s principles). A prospective, randomized, controlled clinical study was carried out on twelve patients with MAFs, divided into two groups. Group A patients were treated with a single 1 - mm 3D titanium miniplate; group B patients were treated with a single 2.0-mm standard titanium miniplate. Patients were followed for 6 months for infection, wound dehiscence, segmental mobility, malocclusion, mouth opening, hardware failure, hardware palpability, paraesthesia, and malunion/non - union. A densitometry analysis was performed using DIGORA software on digital panoramic radiographs to evaluate bone healing. Six complications occurred, representing a total rate of 50%. Three complications occurred in group A and three in group B, with identical complication rates of 50%. No major difference in terms of the radiographic assessment was observed between the two systems | ||
530 | _aIssued also as CD | ||
653 | 4 | _a3D miniplate | |
653 | 4 | _aMandibular angle fractures | |
653 | 4 | _aStandard miniplate | |
700 | 0 |
_aRagia Mohamed Mounair , _eSupervisor |
|
700 | 0 |
_aTarek Ebrahim Elghareeb , _eSupervisor |
|
700 | 0 |
_aTarek Moustafa Elsharkawy , _eSupervisor |
|
856 | _uhttp://172.23.153.220/th.pdf | ||
905 |
_aNazla _eRevisor |
||
905 |
_aSamia _eCataloger |
||
942 |
_2ddc _cTH |
||
999 |
_c54892 _d54892 |