000 | 02983cam a2200349 a 4500 | ||
---|---|---|---|
003 | EG-GiCUC | ||
005 | 20250223031447.0 | ||
008 | 160326s2013 ua dh f m 000 0 eng d | ||
040 |
_aEG-GiCUC _beng _cEG-GiCUC |
||
041 | 0 | _aeng | |
049 | _aDeposite | ||
097 | _aPh.D | ||
099 | _aCai01.09.09.Ph.D.2013.Sa.M | ||
100 | 0 | _aSarah Omar Abduljabar Alariqi | |
245 | 1 | 0 |
_aMarginal gap distance and fracture resistance of two conservative all-ceramic fixed partial denture designs / _cSarah Omar Abduljabar Alariqi ; Supervised Eman Mohamed Anwar , Elzahraa Abdulhameed Eldwakhly , Maha Ahmed Taymour |
246 | 1 | 5 | _aمسافة الفجوة الحافية ومقاومة الكسر لتصميمين محافظين من الأطقم الخزفية الجزئية المثبتة |
260 |
_aCairo : _bSarah Omar Abduljabar Alariqi , _c2013 |
||
300 |
_a164 P. : _bcharts , facsimiles ; _c25cm |
||
502 | _aThesis (Ph.D.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics | ||
520 | _aThe present study aimed to investigate the vertical marginal gap distance and fracture resistance of two conservative all-ceramic fixed partial denture (FPD) designs in comparison to conventional full coverage-retained fixed partial denture. Three models were created by mounting one cast premolar in an acrylic resin block in conjunction with one of the three cast molars with a 10 mm space between them which corresponded to the dimension of a missing first molar. Fifteen posterior full-contour zirconia-based all-ceramic FPDs were fabricated using CAD/CAM technique and divided into three groups of five samples each according to the type of retainer design:- Group (1): Inlay/inlay-retained FPDs with the inlay retainer on both the premolar and molar teeth. Group (2): Inlay/onlay-retained FPDs with a premolar inlay retainer and a molar onlay retainer. Group (3): Full coverage/full coverage-retained FPDs with full coverage retainers on both the premolar and molar teeth. For all FPDs, the vertical marginal gap distance was measured using scanning electron microscope at 400{u00D7} magnification. Each mounted chrome-cobalt dies were duplicated into five epoxy resin models for each tested FPD design. The fifteen FPDs were cemented on their respective epoxy resin models with self-adhesive self-cure resin cement. All samples were loaded and fracture loads (N) were measured at fracture with a computer controlled materials testing machine at a crosshead speed of 1.0 mm/min. | ||
530 | _aIssued also as CD | ||
653 | 4 | _aFull-contour zirconia | |
653 | 4 | _aInlay-retained fixed partial denture | |
653 | 4 | _aMarginal gap distance | |
700 | 0 |
_aElzahraa Abdul-Hameed Eldwakhly , _eSupervisor |
|
700 | 0 |
_aEman Mohamed Anwar , _eSupervisor |
|
700 | 0 |
_aMaha Ahmed Taymour , _eSupervisor |
|
856 | _uhttp://172.23.153.220/th.pdf | ||
905 |
_aNazla _eRevisor |
||
905 |
_aSoheir _eCataloger |
||
942 |
_2ddc _cTH |
||
999 |
_c55739 _d55739 |