000 03228cam a2200349 a 4500
003 EG-GiCUC
005 20250223031455.0
008 160116s2015 ua o f m 000 0 eng d
040 _aEG-GiCUC
_beng
_cEG-GiCUC
041 0 _aeng
049 _aDeposite
097 _aM.Sc
099 _aCai01.09.09.M.Sc.2015.Ab.I
100 0 _aAbdelrahman Mostafa Abdelhakim Mohamed
245 1 0 _aImmunological evaluation of heat cured silicone versus hard acrylic resin in maxillary obturators using elisa test for immunoglobulin a in patients having class I maxillary defects armany classification :
_bA Randomized clinical trial /
_cAbdelrahman Mostafa Abdelhakim Mohamed ; Supervised Ashraf Emil Eskandar , Amr Abdallah , Olfat Gameel Shaker
246 1 5 _aالتقييم الأميونولوجى للسليكونات حرارية الطبخ مقابل راتنج الاكريليك الصلبة فى حالات أصلاح عيوب الفك العلوى المكتسبة باستخدام اختبار ايليزا فى المرضى الذين يعانون من عيوب الصف الأول الفك العلوى تصنيف أرمانى :
_bالتجارب السريرية العشوائية
260 _aCairo :
_bAbdelrahman Mostafa Abdelhakim Mohamed ,
_c2015
300 _a80 P. :
_bphotographs ;
_c25cm
502 _aThesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics
520 _aImmunological evaluation of immunoglobulin a in the oral environment when the hard acrylic resin of the obturator bulb is relined with heat cured silicone in patients having class I maxillary defects Armany classification. This study was conducted to evaluate immunoglobulin a in the oral environment when the hard acrylic resin of the obturator bulb is relined with heat cured silicone 26 patients having unilateral acquired maxillectomy defects were selected to participate in this study Group I: Patients of this group were rehabilitated with heat cured acrylic resin obturator. Group II: Patients of this group were rehabilitated with heat cured silicone bulb obturator zero, two and four weeks evaluation of the obturator was made by measuring the immunoglobulin a in the oral environment using elisa test. Results of this study showed: The silicone lined maxillary obturators showed less colonization than hard acrylic resin obturators. The patients were more satisfied due to ease of insertion and removal as well as greater comfort with obturators lined with heat cured silicone. Conclusion and recommendation: From the results of this study, it can be concluded that within the limitations of this study, both acrylic resin and resilient lining materials could be used as a material for obturator construction in maxillofacial cases
530 _aIssued also as CD
653 4 _aHeat cured silicone versus acrylic resin
653 4 _aMaxillary defects armany
653 4 _aMaxillary obturators
700 0 _aAmr Abdallah ,
_eSupervisor
700 0 _aAshraf Emil Eskandar ,
_eSupervisor
700 0 _aOlfat Gameel Shaker ,
_eSupervisor
856 _uhttp://172.23.153.220/th.pdf
905 _aNazla
_eRevisor
905 _aSamia
_eCataloger
942 _2ddc
_cTH
999 _c56028
_d56028