000 03645cam a2200337 a 4500
003 EG-GiCUC
005 20250223031457.0
008 160420s2015 ua d f m 000 0 eng d
040 _aEG-GiCUC
_beng
_cEG-GiCUC
041 0 _aeng
049 _aDeposite
097 _aM.Sc
099 _aCai01.09.03.M.Sc.2015.Om.M
100 0 _aOmar Osama Shaalan
245 1 0 _aMicroshear bond strength evaluation of self adhering flowable composite to enamel and dentin /
_cOmar Osama Shaalan;Supervised Amira Farid El Zoghby, Shereen Hafez Ibrahim
246 1 5 _aتقييم قوة الربط القصية الدقيقة للكمبوزيت القابل للتسييل ذاتي اللصق مع المينا و العاج السني
260 _aCairo :
_bOmar Osama Shaalan ,
_c2015
300 _a100 P. :
_bcharts ;
_c25cm
502 _aThesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Operative Dentistry
520 _aThis study was conducted to evaluate microshear bond strength of self adhering flowable composite to enamel and dentin, without surface treatment and after different surface treatment protocols compared to flowable composite. Thirty two carious free extracted molars were selected in the current study. The teeth were wet ground to expose fresh flat enamel or dentin surfaces where each surface will carry five specimens. Teeth were randomly divided into two main groups according to restorative tested material; either flowable composite (Filtek{u2122} Z350 XT Flowable) or self-adhering composite (Fusio{u2122}Liquid Dentin). Each group was divided into four subgroups according to surface pretreatment; either without any surface treatment, with acid etching only, with self etching adhesive system and with etch and rinse bonding system. Each subgroup was divided into two classes according to type of substrate; either enamel or dentin. Sixteen subgroups were created (n=10) with a total number of 160 specimens. A plastic tube (tygon tube), 0.7 mm in diameter and 1mm in length was held securely and immobilized using cotton pliers on the indicated substrate with or without surface treatment, then was restored for microshear bond strength testing according to manufacturer instructions. Microshear bond strength test was conducted immediately after 24 hours using universal testing machine at crosshead speed of 0.5 mm/min till specimens fail, bond strength was calculated and failure modes were analyzed. The results showed that Filtek{u2122} Z350 XT Flowable with surface treatment using etch and rinse bonding system has the highest statistically significant bond strength to enamel, while least statistically significant bond strength was for Fusio{u2122}Liquid Dentin with surface treatment using self etch system and without any surface pretreatment. In dentin, the highest statistically significant bond strength was for Fusio{u2122}Liquid Dentin with surface treatment using self etch system, while the least bond strength was for Fusio{u2122}Liquid Dentin with etching only and Fusio{u2122}Liquid Dentin without surface treatment, in addition applying Filtek{u2122} Z350 XT Flowable without surface treatment following manufacturer instructions showed premature failure for both enamel and dentin
530 _aIssued also as CD
653 4 _aComposite
653 4 _aEnamel and dentin
653 4 _aMicroshear bond strength
700 0 _aAmira Farid El Zoghby ,
_eSupervisor
700 0 _aShereen Hafez Ibrahim ,
_eSupervisor
856 _uhttp://172.23.153.220/th.pdf
905 _aAml
_eCataloger
905 _aNazla
_eRevisor
942 _2ddc
_cTH
999 _c56110
_d56110