000 03032cam a2200349 a 4500
003 EG-GiCUC
005 20250223031503.0
008 160505s2015 ua o f m 000 0 eng d
040 _aEG-GiCUC
_beng
_cEG-GiCUC
041 0 _aeng
049 _aDeposite
097 _aM.Sc
099 _aCai01.09.09.M.Sc.2015.No.T
100 0 _aNorhan Naief Abdelhaliem Youssef
245 1 2 _aA three dimensional evaluation of the accuracy of "Express XT" vinyl polysiloxane impression material using spray and immersion disinfection techniques with immediate and delayed pouring times :
_bIn vitro study /
_cNorhan Naief Abdelhaliem ; Supervised Amina Abdellatif Zaki , Maha Ahmed Taymour , Tamer Moneir Mousa Nassef
246 1 5 _aتقويم ثلاثى الأبعاد لدقه طبعه الفينيل بولى سيلوكسين اكسبرس اكس تى بإستخدام تقنيات تطهير بالرش و الغمر مع الصب الفورى و المؤجل :
_bدراسة معملية
260 _aCairo :
_bNorhan Naief Abdelhaliem Youssef ,
_c2015
300 _a90 P. :
_bphotographs ;
_c25cm
502 _aThesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics
520 _aThe aim of this study was to evaluate the dimensional accuracy of the recently introduced vinyl polysiloxane impression material "Express XT" when subjected to sprayed disinfection with cavicide1 disinfectant solution at two different pouring times. Using three dimensional DicoMesher software version3. A total of twenty impressions of a standardized stainless steel mold were made using express XT impression material in specially fabricated trays. The impressions were subjected to spray disinfection protocol using cavicide 1 disinfectant solution and then divided according to times of pouring into two groups immediate pour according to manufactures instructions and One-week delay pouring. Impressions were poured with a type IV extra hard dental stone. All measurements were performed on the photos of the produced cast by DicoMesher software a computer software program allowing three dimension recording. Results were statistically analyzed. Immediate pouring time showed the lowest mean overall dimensional changes while delayed pouring time showed higher mean shrinkage. However, there was no statistically significant difference between the overall dimensional changes of the two groups. Within the limitation of this study we concluded that different pouring times did not harm the dimensional stability of the die material
530 _aIssued also as CD
653 4 _aExpress XT" vinyl polysiloxane
653 4 _aImpression material using spray
653 4 _aThree dimensional of the accuracy
700 0 _aAmina Abdellatif Zaki ,
_eSupervisor
700 0 _aMaha Ahmed Taymour ,
_eSupervisor
700 0 _aTamer Moneir Mousa Nassef ,
_eSupervisor
856 _uhttp://172.23.153.220/th.pdf
905 _aNazla
_eRevisor
905 _aSamia
_eCataloger
942 _2ddc
_cTH
999 _c56281
_d56281