000 02968cam a2200337 a 4500
003 EG-GiCUC
005 20250223031511.0
008 160519s2015 ua h f m 000 0 eng d
040 _aEG-GiCUC
_beng
_cEG-GiCUC
041 0 _aeng
049 _aDeposite
097 _aM.Sc
099 _aCai01.09.09.M.Sc.2015.As.I
100 0 _aAshraf Mohammad Ayman Dabbousi
245 1 0 _aInfluence of finish line design on the vertical marginal discrepancy and fracture resistance of enamic hybrid ceramic :
_bIn vitro study /
_cAshraf Mohammad Ayman Dabbousi ; Supervised Rabab Mohammed Ibrahim , Rana Mahmoud Sherif
246 1 5 _aتأثير شكل خط الانهاء على التباين الحافي العمودي و مقاومة الانكسار للسيراميك المهجن - إينامك :
_bدراسة مخبرية
260 _aCairo :
_bAshraf Mohammad Ayman Dabbousi ,
_c2015
300 _a86 P. :
_bcharts , facsimiles ;
_c25cm
502 _aThesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics
520 _aThis study was conducted to evaluate the effect of finish line design on theMarginal fit, and fracture resistance of the Hybrid ceramic Vita Enamic. According to the sample size calculation, a total of 16 crowns were constructed. The samples were divided into two equal groups (n=8) according to the finish line design: Group (A): 8 samples (n=8) Chamfer finish line design1mm (Ac). Group (B): 8 samples (n=8) Shoulder finish line design 1mm (Bs). Two stainless steel dies were machine milled to simulate a tooth preparation for a ceramic crown of a mandibular second molarwith two finish line configurations 1mm chamfer and 1 mm shoulder. Each die was 6-mm in height, 8-mm in cervical diameter, 6mm in occlusal diameter and had a total occlusal convergence of 16o. Digitalization of both dies and milling of hybrid restorations was made using CAD-CAM technology .The stainless steel dies were duplicated into epoxy resin ones using Silicone impression material, and the marginal gap was evaluated on the stainless steel dies using digital microscope,while fracture resistance was measured using epoxy resin die with the corresponding hybrid restoration. The restorations were surface treated according to the manufacturer{u2019}s instructions, and cemented on the epoxy resin dies using self-adhesive resin cement, after 24 hours of storage in distilled water, the fracture resistance of the restorations was measured using universal testing machine with load of 5 kN and at a cross head speed of 1mm/min
530 _aIssued also as CD
653 4 _aEnamic hybrid ceramic
653 4 _aFracture resistance
653 4 _aVertical marginal discrepancy
700 0 _aRabab Mohammed Ibrahim ,
_eSupervisor
700 0 _aRana Mahmoud Sherif ,
_eSupervisor
856 _uhttp://172.23.153.220/th.pdf
905 _aAml
_eCataloger
905 _aNazla
_eRevisor
942 _2ddc
_cTH
999 _c56545
_d56545