000 03063cam a2200337 a 4500
003 EG-GiCUC
005 20250223031523.0
008 160618s2015 ua dh f m 000 0 eng d
040 _aEG-GiCUC
_beng
_cEG-GiCUC
041 0 _aeng
049 _aDeposite
097 _aM.Sc
099 _aCai01.09.03.M.Sc.2015.No.M
100 0 _aNour Eldin Ibrahim Amin
245 1 0 _aMicro shear bond strength of resin composite to tooth substrates treated with acid etching or conditioned by laser :
_bAn in vitro study /
_cNour Eldin Ibrahim Amin ; Supervised Amira Farid Elzoghby , Asmaa Yousef Harhash
246 1 5 _aقوة الربط القصّى للراتنج مع مينا و عاج السن المعالج بالتخريش و الغسيل أو مهيأ بالليزر الحيوى :
_bدراسة معملية
260 _aCairo :
_bNour Eldin Ibrahim Amin ,
_c2015
300 _a68 P. :
_bcharts , facsimiles ;
_c25cm
502 _aThesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Operative Dentistry
520 _aThis in vitro study was carried out to assess the shear bond strength of composite resin bonded to enamel and dentin pretreated with acid etchant and Er, Cr : Ysgg. Non carious 66 sound human premolars were selected to prepare 132 specimens for this study. Buccal surfaces were flattened and were ground under copious water coolant to obtain a flat enamel surface while the lingual surfaces were ground to obtain a uniform flat surface of superficial dentin. Subsequently, the surfaces were polished with 240 grit, 400 grit and 600 grit sandpaper disks to standardize the smear Layer. Prepared specimens were randomly divided into two main groups, 66 specimens each, according to etching methods (A); group (A1) etching by an Er, Cr: YSGG laser system (Waterlase MD, Biolase); and (A2) etching by phosphoric acid using Scotchbond Universal Etchant. Each group was further divided into two subgroups 33 specimens each according to tooth substrate tested (S); where (S1) was for enamel, while (S2) was for dentin. Each subgroup was divided into three classes 11 specimens each according to storage time (T); stored for 1 day (T1), stored for 7 days (T2) and stored for 30 days (T3). The adhesive was applied on the substrate and cured then a plastic tube (Tygon tube), 0.7 mm in diameter and 1mm in length was held securely and immobilized using cotton pliers on the indicated substrate. Then resin composite (Z 350 XT) was packed into the tube and cured. Microshear bond strength test was conducted using universal testing machine at crosshead speed of 0.5 mm/min till specimens fail, bond strength was calculated in MPs
530 _aIssued also as CD
653 4 _aLaser-etched enamel
653 4 _aLowest significantmicroshear
653 4 _aStrength mean compared
700 0 _aAmira Farid Elzoghby ,
_eSupervisor
700 0 _aAsmaa Yousef Harhash ,
_eSupervisor
856 _uhttp://172.23.153.220/th.pdf
905 _aNazla
_eRevisor
905 _aSamia
_eCataloger
942 _2ddc
_cTH
999 _c56960
_d56960