000 03247cam a2200337 a 4500
003 EG-GiCUC
005 20250223031702.0
008 170314s2014 ua h f m 000 0 eng d
040 _aEG-GiCUC
_beng
_cEG-GiCUC
041 0 _aeng
049 _aDeposite
097 _aM.Sc
099 _aCai01.09.13.M.Sc.2014.Mo.S
100 0 _aMohammed Adel Abdelfattah Mohammed
245 1 4 _aThe single 2.0mm Ao locking reconstruction plate versus the conventional plate system in treating two lines of linear mandibular Fracture =
_bاستخدام الشرائح التثبيتيه المفرده ذات الإطباق بسمك 2مم ضد الشرائح العاديه فى علاج الكسور الخطيه للفك السفلى فى مكانين /
_cMohammed Adel Abdelfattah Mohammed ; Supervised Kadri Mohamed Nasr , Hassan Gamal Sadek
246 1 5 _aاستخدام الشرائح التثبيتيه المفرده ذات الإطباق بسمك 2مم ضد الشرائح العاديه فى علاج الكسور الخطيه للفك السفلى فى مكانين
260 _aCairo :
_bMohammed Adel Abdelfattah Mohammed ,
_c2014
300 _a80 P. :
_bfacsimiles ;
_c25cm
502 _aThesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Oral and Maxillofacial Surgery
520 _aThis study was conducted to compare between the rigidity of fixation between conventional 2mm plates and the reconstruction 2mm plates in cases of two lines of linear mandibular fracture. The results assessed by degree of bone density through radiographic evaluation preoperatively then immediately postoperatively, one month, two months, three months postoperatively. A total of 10 patients suffered from 2 lines of linear mandibular fracture divided into 2 groups five patients each. Group (A) treated with conventional 2mm plates and screws two plates for each fracture line (rigid fixation). Group (B) treated with locking 2mm plates and locking head screws one plate for each fracture line, three screws on each side of the fracture line (rigid fixation). Data collected by radiographic images taken preoperatively , one month, two months, three months postoperatively. Digitalized images were manipulated using the specially designed software of the digora system. On each digital image, the mean gray value of the marked region of interest was calculated using the line measurement facility of the software. This was performed by drawing lines along the whole length of the fracture line. The clinical results assessed infection rate, range on mandibular movement, post operative numbness and wound dehiscence. No signs of infection or wound dehiscence recorded throughout the follow up period, range of mandibular movement increased from 19-24mm preoperatively to 22-26mm immediately postoperatively to 40-45mm by the end three months postoperatively
530 _aIssued also as CD
653 4 _aLocking plates
653 4 _aMandibular fracture
653 4 _aRigid fixation
700 0 _aHassan Gamal Sadek ,
_eSupervisor
700 0 _aKadri Mohamed Nasr ,
_eSupervisor
856 _uhttp://172.23.153.220/th.pdf
905 _aNazla
_eRevisor
905 _aSamia
_eCataloger
942 _2ddc
_cTH
999 _c60251
_d60251