000 | 02677cam a2200337 a 4500 | ||
---|---|---|---|
003 | EG-GiCUC | ||
005 | 20250223031734.0 | ||
008 | 170617s2015 ua o f m 000 0 eng d | ||
040 |
_aEG-GiCUC _beng _cEG-GiCUC |
||
041 | 0 | _aeng | |
049 | _aDeposite | ||
097 | _aM.Sc | ||
099 | _aCai01.09.09.M.Sc.2015.Sa.E | ||
100 | 0 | _aSahar Ahmed Abdelbaky Shawer | |
245 | 1 | 0 |
_aEvaluation of surface roughness of thermoplastic denture base material in comparison with conventional poly-methyl methacrylate : _bIn-vitro study / _cSahar Ahmed Abdelbaky Shawer ; Supervised Amal Fathy Kaddah , Khaled Aziz |
246 | 1 | 5 | _aتقييم خشونة سطح قاعدة طقم الاسنان المكون من مادة الثيرموبيلاستيك بالمقارنه مع الماده التقليديه بولى - الميثيل ميتاكريليت |
260 |
_aCairo : _bSahar Ahmed Abdelbaky Shawer , _c2015 |
||
300 |
_a68 P. : _bphotographs ; _c25cm |
||
502 | _aThesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics | ||
520 | _aThe present study was conducted to evaluate surface roughness of thermoplastic denture base material (Bre-crystal) in comparison with conventional polymethylmethacrylate acrylic denture base material (acrostone) for polished and unpolished (fitting) surfaces. Twenty completely edentulous patients were selected from outpatient clinic of prosthodontics department, Faculty of oral and dental Medicine, Cairo university. The patient were motivated and monitored for the maintenance of good oral hygiene. Participants were informed about the nature of the study and signed an informed consent form. Patients who agreed to sign this consent form were considered. This study was carried out on two groups of patients. Each group comprised ten patients. Group I:Each patient in this group received a complete denture with Thermoplastic denture base material (Bre-crystal) (BredentCompany,Senden Germany). Group II: Each patient in this group received a complete denture with conventional heat cured denture base material(polymethylmethacrylateacrylic denture base material) (Acrostone). Surfaces roughness was evaluated for the pervious groups-fitting and polished surfaces by mechanical stylus profilemeter taylor hobson | ||
530 | _aIssued also as CD | ||
653 | 4 | _aMethyl methacrylate | |
653 | 4 | _aSurface roughness | |
653 | 4 | _aThermoplastic denture base material | |
700 | 0 |
_aAmal Fathy Kaddah , _eSupervisor |
|
700 | 0 |
_aKhaled Aziz , _eSupervisor |
|
856 | _uhttp://172.23.153.220/th.pdf | ||
905 |
_aNazla _eRevisor |
||
905 |
_aSamia _eCataloger |
||
942 |
_2ddc _cTH |
||
999 |
_c61258 _d61258 |