000 03710cam a2200337 a 4500
003 EG-GiCUC
005 20250223031944.0
008 180318s2016 ua dh f m 000 0 eng d
040 _aEG-GiCUC
_beng
_cEG-GiCUC
041 0 _aeng
049 _aDeposite
097 _aM.Sc
099 _aCai01.09.07.M.Sc.2016.Ha.E
100 0 _aHazim Fawzy Elmoabayed
245 1 0 _aEvaluation of shear bond strength of Fuji IX and Riva with and without salivary contamination on deciduous molars :
_bAn in- vitro study /
_cHazim Fawzy Elmoabayed ; Supervised Sherif Bahget , Rania Abdullah
246 1 5 _aتقييم قوة رابطة القص في الريفا و الفوجي 9 مع و بدون التلوث اللعابي علي الضروس اللبنية:
_bدراسة معملية
260 _aCairo :
_bHazim Fawzy Elmoabayed ,
_c2016
300 _a78 P. :
_bcharts , facsimiles ;
_c25cm
502 _aThesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Pedodontics
520 _aThis study was performed to evaluate the shear bond strengths of GC Fuji IX GP and Riva resin modified glass ionomer as a filling material of deciduous molars with and without salivary contamination by using instron universal testing Machine (an in-vitro study).Shear bond strength of investigating materials to middle of the dentin of primary molars after 24 hours. A totalone hundred and forty tooth caries free freshly extracted or sheded second primary molars were utilized in this study. The tooth was divided into two main groups according to material used in which the group I GC Fuji IX GP (n = 60) and divided into three subgroups, each group contain twenty primary molars with and without salivary contamination while group II Riva SDI (n= 80) in which divided into four subgroups each group contain twenty primary molars with and without salivary contamination.Theocclusal surface of molars was grounded by diamond disc into the flat dentin surface, which materials were applied according to their manufacture's instructions Fuji IX and Riva glass ionomers was applied in pediatric catheter sections (1 inch in diameter and 1 inch in hight) were constructed on the occlusal surface of specimens.In the salivary contaminated subgroups, the dentinal surface was contaminated with human saliva by using a dropper,After 1 minute, the saliva was blotted drywith tissue paper, the mixed filling was placed on the dentin surface with a gentle pressure by using the applier to which shear force was applied to a failure using a universal testing machine at a crosshead speed of 0.5 mm/minute. The results of the present studyin the group I GC Fuji IX GP, It found the Fuji IX regular without saliva contamination recorded statistically significant (P<0.05) the heighest shear bond strength mean value (3.32 ± 0.51 MPa) while Fuji IX fast with saliva contamination recorded statistically significant (P<0.05) the heighest shear bond strength mean value (3.35 ± 0.45 MPa) , on other hand, in the groupIIRiva SDI , It found the riva light cure regular without saliva contamination recorded statistically significant (P<0.05) the highest shear bond strength mean value (8.173 ± 2.7 MPa), also, with sailiva contamination recorded statistically significant (P<0.05) the highest shear bond strength mean value (7.03 ± 1.7 MPa)
530 _aIssued also as CD
653 4 _aBond strength
653 4 _aGlass-ionomers
653 4 _aSalivary contamination
700 0 _aRania Abdullah ,
_eSupervisor
700 0 _aSherif Bahget ,
_eSupervisor
856 _uhttp://172.23.153.220/th.pdf
905 _aNazla
_eRevisor
905 _aShimaa
_eCataloger
942 _2ddc
_cTH
999 _c65471
_d65471