000 | 03190cam a2200349 a 4500 | ||
---|---|---|---|
003 | EG-GiCUC | ||
005 | 20250223032001.0 | ||
008 | 180428s2017 ua dh f m 000 0 eng d | ||
040 |
_aEG-GiCUC _beng _cEG-GiCUC |
||
041 | 0 | _aeng | |
049 | _aDeposite | ||
097 | _aPh.D | ||
099 | _aCai01.09.09.Ph.D.2017.Ah.I | ||
100 | 0 | _aAhmed Mohammed Abukhalil Ali Keshk | |
245 | 1 | 0 |
_aImpact of CAD-CAM designed telescopic crown retainers versus conventional clasp on the quality of life and muscle activity for patients restored by mandibular distal extension removable partial dentures : _bRandomized Clinical Trail / _cAhmed Mohammed Abukhalil Ali Keshk ; Supervised Amal Fathy Kaddah , Ahmed Emad Fayyad , Eman Ahmed Maher |
246 | 1 | 5 |
_aتأثير التيجان التلسكوبية المصممة بواسطة الكمبيوتر مقابل العروة المثبته على نوعية الحياة ونشاط العضلات بالنسبة للمرضي المعوضين باطقم جزئية خلفية الامتداد بالفك السفلي : _bدراسة سريرية عشوائية |
260 |
_aCairo : _bAhmed Mohammed Abukhalil Ali Keshk , _c2017 |
||
300 |
_a169 P. : _bcharts , facsimiles ; _c25cm |
||
502 | _aThesis (Ph.D.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics | ||
520 | _aBackground:Posterior distal extension partial denture present a number of design challenges. Especially the equitable distribution of forces that may become adverse during functional and parafunctional activities. So to maintain remaining alveolar ridges and teeth in an optimal state of health and to provide the patient with improved comfort and function,these forces are often compensated for to some extent by framework and denture base design variation. Purpose:The aim of this study was to evaluate the quality of life and muscle activity for patients restored by mandibular distal extension removable partial dentures (MDERPD)that retained either by CAD-CAM designed telescopic crown retainers or CAD-CAM designed conventional clasp.Materials and Methods: 42 partially edentulous patients were selected and randomly allocated into two identical groups. Group (1) Received a (MDERPD) retained with CAD-CAM designed telescopic crown retainers. Group (2) Received a (MDERPD) retained with CAD-CAM designedconventional clasp. Each group evaluated as regarding the quality of life through the Arabic version of OHIP-EDENT questionnaire. The digital electromyography (EMG) is used to record the muscle activity of anterior temporalis and masseter muscles. Conclusion:CAD-CAM designed telescopic crown retained RPD improved the quality of life and muscle activity of partially edentulous patients more than CAD-CAM designed clasp retained RPD | ||
530 | _aIssued also as CD | ||
653 | 4 | _aBall | |
653 | 4 | _aCAD-CAM | |
653 | 4 | _aTelescopic attachment | |
700 | 0 |
_aAhmed Emad Fayyad , _eSupervisor |
|
700 | 0 |
_aAmal Fathy Kaddah , _eSupervisor |
|
700 | 0 |
_aEman Ahmed Maher , _eSupervisor |
|
856 | _uhttp://172.23.153.220/th.pdf | ||
905 |
_aNazla _eRevisor |
||
905 |
_aShimaa _eCataloger |
||
942 |
_2ddc _cTH |
||
999 |
_c66030 _d66030 |