000 03190cam a2200349 a 4500
003 EG-GiCUC
005 20250223032001.0
008 180428s2017 ua dh f m 000 0 eng d
040 _aEG-GiCUC
_beng
_cEG-GiCUC
041 0 _aeng
049 _aDeposite
097 _aPh.D
099 _aCai01.09.09.Ph.D.2017.Ah.I
100 0 _aAhmed Mohammed Abukhalil Ali Keshk
245 1 0 _aImpact of CAD-CAM designed telescopic crown retainers versus conventional clasp on the quality of life and muscle activity for patients restored by mandibular distal extension removable partial dentures :
_bRandomized Clinical Trail /
_cAhmed Mohammed Abukhalil Ali Keshk ; Supervised Amal Fathy Kaddah , Ahmed Emad Fayyad , Eman Ahmed Maher
246 1 5 _aتأثير التيجان التلسكوبية المصممة بواسطة الكمبيوتر مقابل العروة المثبته على نوعية الحياة ونشاط العضلات بالنسبة للمرضي المعوضين باطقم جزئية خلفية الامتداد بالفك السفلي :
_bدراسة سريرية عشوائية
260 _aCairo :
_bAhmed Mohammed Abukhalil Ali Keshk ,
_c2017
300 _a169 P. :
_bcharts , facsimiles ;
_c25cm
502 _aThesis (Ph.D.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics
520 _aBackground:Posterior distal extension partial denture present a number of design challenges. Especially the equitable distribution of forces that may become adverse during functional and parafunctional activities. So to maintain remaining alveolar ridges and teeth in an optimal state of health and to provide the patient with improved comfort and function,these forces are often compensated for to some extent by framework and denture base design variation. Purpose:The aim of this study was to evaluate the quality of life and muscle activity for patients restored by mandibular distal extension removable partial dentures (MDERPD)that retained either by CAD-CAM designed telescopic crown retainers or CAD-CAM designed conventional clasp.Materials and Methods: 42 partially edentulous patients were selected and randomly allocated into two identical groups. Group (1) Received a (MDERPD) retained with CAD-CAM designed telescopic crown retainers. Group (2) Received a (MDERPD) retained with CAD-CAM designedconventional clasp. Each group evaluated as regarding the quality of life through the Arabic version of OHIP-EDENT questionnaire. The digital electromyography (EMG) is used to record the muscle activity of anterior temporalis and masseter muscles. Conclusion:CAD-CAM designed telescopic crown retained RPD improved the quality of life and muscle activity of partially edentulous patients more than CAD-CAM designed clasp retained RPD
530 _aIssued also as CD
653 4 _aBall
653 4 _aCAD-CAM
653 4 _aTelescopic attachment
700 0 _aAhmed Emad Fayyad ,
_eSupervisor
700 0 _aAmal Fathy Kaddah ,
_eSupervisor
700 0 _aEman Ahmed Maher ,
_eSupervisor
856 _uhttp://172.23.153.220/th.pdf
905 _aNazla
_eRevisor
905 _aShimaa
_eCataloger
942 _2ddc
_cTH
999 _c66030
_d66030