000 03808cam a2200337 a 4500
003 EG-GiCUC
005 20250223032014.0
008 180606s2017 ua dh f m 000 0 eng d
040 _aEG-GiCUC
_beng
_cEG-GiCUC
041 0 _aeng
049 _aDeposite
097 _aM.Sc
099 _aCai01.09.03.M.Sc.2017.Mo.M
100 0 _aMohamed Mahrous Elsabbagh
245 1 0 _aMicrotensile bond strength of self- adhesive resin composite to caries affected dentin created by excavating ceramic versus tungsten carbide burs :
_ban in-vitro Study /
_cMohamed Mahrous Elsabbagh ; Supervised Mostafa Abdalfameed Mostafa , Amir Hafez Ibrahim
246 1 5 _aقوة رابطة الشد الدقى للكمبوزيت الراتنجي ذاتي اللصق للعاج المتضرر بالتسوس والناشئ بالتجريف بواسطة السنابل الخزفية مقابل سنابل كربيد التنجستين :
_bدراسة معملية
260 _aCairo :
_bMohamed Mahrous Elsabbagh ,
_c2017
300 _a67 P. :
_bcharts , facsimiles ;
_c25cm
502 _aThesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Operative Dentistry
520 _aThis study was conducted to evaluate microtensile bond strength of self - adhesive resin composite strength to caries- affected dentin created by excavating ceramic versus tungsten carbide burs and to assess tooth - restoration interface using environmental scanning electron microscope (ESEM).. Subjects and Methods : A total number of 102 specimens collected out of 42 freshly extracted permanent human carious teeth with medium to large carious lesions were selected in this study. The specimens was randomly divided into three groups according to type of dentin with 30 specimens each, sound dentin, dentin excavation using ceramic bur and dentin excavation using tungsten bur then all specimens was restored with self - adhesive resin composite. Each group will be further divided into two subgroups according to storage period 24 hours storage, three month storage with 15 specimens each group. Each tooth was split through the middle of carious lesion, to use both dentin sides excavating ceramic and tungsten carbide burs at low speed on the same tooth till effective removal of the carious lesion. The caries was monitored by checking hardness of dentin with dental explorer, in addition to caries detection dye. Results: The result of the present study revealed that in both 24 hours and three months, the Sound dentin recorded the highest mean microtensile bond strength followed by caries dentin excavated by Tungsten carbide bur then caries dentin excavated by Ceramic bur (Cera Bur) with no significant between them. For interfacial analysis, the photomicrographs showed that in 24 hours a superficial interaction between self-adhesive flowable resin composite and both sound and bur-cut dentin with resin infiltrated smear layer and absence resin tag formation. While after three month, a gap was detected between self-adhesive flowable resin composite and dentin with absence resin tag. Conclusion: Using ceramic or carbide bur in caries removal did not influence the bond strength of self - adhesive flowable resin composite to caries-affected dentin.The time interval is the most critical factor affecting the bond strength of self adhesiveflowable composite rather than the caries-excavation method
530 _aIssued also as CD
653 4 _aAdhesive Resin
653 4 _aBond Strength of Self
653 4 _aCaries Affected Dentin Created
700 0 _aAmir Hafez Ibrahim ,
_eSupervisor
700 0 _aMostafa Abdalfameed Mostafa ,
_eSupervisor
856 _uhttp://172.23.153.220/th.pdf
905 _aNazla
_eRevisor
905 _aShimaa
_eCataloger
942 _2ddc
_cTH
999 _c66495
_d66495