000 03121cam a2200337 a 4500
003 EG-GiCUC
005 20250223032015.0
008 180609s2017 ua dh f m 000 0 eng d
040 _aEG-GiCUC
_beng
_cEG-GiCUC
041 0 _aeng
049 _aDeposite
097 _aM.Sc
099 _aCai01.09.05.M.Sc.2017.Ya.A
100 0 _aYasmin Aboulmaaty Mogahed
245 1 0 _aAssessment of simulated mandibular condylar erosions in cone beam ct imagedwith two different voxel sizes :
_ba diagnostic accuracy study /
_cYasmin Aboulmaaty Mogahed ; Supervised Noha Saleh M. Abutaleb , Hany Mahmoud Omar
246 1 5 _aتقييم التآكلات العظميه المحاكاه بلقمة الفك السفلى فى الآشعة المقطعية بالحاسوب مخروطية الشعاع المأخوذه باستخدام مقاسين مختلفين من وحدة الحجم :
_bدراسة دقة تشخيصيه
260 _aCairo :
_bYasmin Aboulmaaty Mogahed ,
_c2017
300 _a184 P. :
_bcharts , facsimiles ;
_c25cm
502 _aThesis (M.Sc.) - Cairo University -Faculty of Oral and Dental Medicine - Department of Oral Radiology and Diagnosis
520 _aObjectives: to evaluate the effect of using two different voxel sizes on the accuracy of Cone Beam Computed Tomography images for detection of simulated mandibular condylar erosions. Materials and methods: twelve dry human mandibles (24 condyles) were selected and Simulated erosions were drilled with variable bur sizes at different depths on the five condylar surfaces (superior, anterior, posterior, medial and lateral surfaces). The mandibles were scanned using normal and high resolution protocols (voxel sizes: 0.4mm and 0.2mm respectively). Results: Results of the current study revealed that with the CBCT normal resolution protocol (voxel sizes: 0.4mm), the sensitivity of detection of the simulated defects ranged from 87.05% to 94.96% and the accuracy values from 88.9% to 95.86% among the observers. However, higher values were found with the high resolution protocol (voxel sizes: 0.2mm) where the sensitivity values increased to the range of 93.53% to 97.84% and also did the accuracy values with range of 94.44% to 98.15%. Conclusion: In CBCT Despite the higher sensitivity and diagnostic accuracy values of CBCT high resolution protocol both normal and high resolution protocols (voxel sizes: 0.4mm and 0.2mm respectively) were comparable in detection of the simulated mandibular condylar erosions as verified by the very good and significant intra-observer agreements.However, the moderate to good inter-observer agreement pointed out that the differences in agreement might be due to differences in the observer experience more than the difference in the scan protocol
530 _aIssued also as CD
653 4 _aCBCT
653 4 _aCondylar erosions
653 4 _aTMJ disorders
700 0 _aHany Mahmoud Omar ,
_eSupervisor
700 0 _aNoha Saleh M. Abutaleb ,
_eSupervisor
856 _uhttp://172.23.153.220/th.pdf
905 _aNazla
_eRevisor
905 _aShimaa
_eCataloger
942 _2ddc
_cTH
999 _c66512
_d66512