000 03245cam a2200337 a 4500
003 EG-GiCUC
005 20250223032033.0
008 180825s2017 ua dh f m 000 0 eng d
040 _aEG-GiCUC
_beng
_cEG-GiCUC
041 0 _aeng
049 _aDeposite
097 _aPh.D
099 _aCai01.09.09.Ph.D.2017.Ah.E
100 0 _aAhmad Zakaria Ali Aladl
245 1 0 _aEffect of using equator versus self-aligning attachment on quality of life and overdenture retention for patients restored by implant-retained mandibular overdentures :
_bRandomized clinical trial /
_cAhmad Zakaria Ali Aladl ; Supervised Amal Fathy Kaddah , Ahmed Emad Fayyad
246 1 5 _aدراسة تأثير استخدام وصلات الإكويتور مقابل الوصلات ذاتية المحاذاه على درجه استبقاء الاطقم السفليه المثبته علي غرسات حامله مع فحص كفاءة الحياه لكل منهما :
_bدراسة سريرية عشوائية
260 _aCairo :
_bAhmad Zakaria Ali Aladl ,
_c2017
300 _a106 P. :
_bcharts , facsimiles ;
_c25cm
502 _aThesis (Ph.D.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontic
520 _aTwo implant retained mandibular overdenture is a simple solution in rehabilitation of edentulous patients. Equator attachment offers a lower profile than the self-aligning attachment but there is no enough researches that compare between them. Aim: Clinically compare between both groups regarding oral health related quality of life and overdenture retention in edentulous patients restored with implant overdenture. Material and Methods: Complete denture fabricated, then two implants placed at the canine region. Equator attachments connected to group I and self-aligning attachments connected to each group II. The Arabic version of the oral health impact profile for the edentulous patients was used specifically to evaluate the impact of implant prosthesis on the patient's quality of life. Overdenture retention was measured according to the method reported by (Jose F. Mañes et al., 2011) using a spring scale to measure retention strength (in newton). Results: Regarding oral health related quality of life, there was statistically significant improvement from time of insertion to 3 months in both groups. There was no statistically significant difference between both groups at insertion time and after 3 months. Regarding overdenture retention, there was decrease of retention from time of insertion to 3 months follow-up periods with statistically significant difference in both groups of study. Equator group showed statistically significant more retention force compared to that of locator group at time of insertion, however, there was no statistically significant difference between two groups at 3 months follow-up period
530 _aIssued also as CD
653 4 _aEquator attachment
653 4 _aQuality of Life
653 4 _aSelf-Aligning attachment
700 0 _aAhmed Emad Fayyad ,
_eSupervisor
700 0 _aAmal Fathy Kaddah ,
_eSupervisor
856 _uhttp://172.23.153.220/th.pdf
905 _aNazla
_eRevisor
905 _aShimaa
_eCataloger
942 _2ddc
_cTH
999 _c67129
_d67129