000 03693cam a2200349 a 4500
003 EG-GiCUC
005 20250223032053.0
008 181001s2017 ua dh f m 000 0 eng d
040 _aEG-GiCUC
_beng
_cEG-GiCUC
041 0 _aeng
049 _aDeposite
097 _aPh.D
099 _aCai01.24.05.Ph.D.2017.Yo.A
100 0 _aYosria Kamal Khattab
245 1 0 _aApplying laser in a drip irrigation system automatically for some vegetable crops /
_cYosria Kamal Khattab ; Supervised Helmy Elsayed Hassan Mohamed , Mohamed Essam Eldin Shawkey , Ayman Mahmoud Ahmed Abouelmagd
246 1 5 _aأستخدام الليزر في نظام الرى بالتنقيط الاتوماتيكيا لبعض محاصيل الخضر
260 _aCairo :
_bYosria Kamal Khattab ,
_c2017
300 _a120 P. :
_bcharts , facsimiles ;
_c25cm
502 _aThesis (Ph.D.) - Cairo University - National Institute of Laser Enhanced Science - Department of Laser Applications in Enviroanmental Metrology Photochemistry and Agriculture
520 _aThe purpose of this study is to use the laser technology in applicable for automating drip irrigation systems, to manage and operate the drip irrigation system, and to save water and energy and high production. In this research a new instrument of Laser Control Unit (LCU) is design and built in laser institute Cairo University. The new instrument is consists of laser sours, sensor and micro control unit. The use of LCU depends on the optical properties of leaf such as transmittance, reflectance and absorption of laser beam. The correlation between leaf water content and laser beam transmitted from leaves (LBT) was used to detect when the automate irrigation system operate and how much water applied. Three experimental was carried at laboratory, greenhouse and open field. The first experimental was carried in lab of laser institute to test the LCU, with use of many leaves for different plant, vegetable crop (cucumber and squash), fruit and decoration plants. The values of laser beam transmitted from leaves which recorded in micro controller unit was used to establish the value of LBT by mV which used to operate the automate drip irrigation system for fully, moderate and deficit water regime to irrigate different plants. Secondly experiment was carried in greenhouse for vegetable crop (cucumber and squash) used the LCU and the values of LBT by mV which the automate system. The data of LCU was recorded in data logger in said the LCU, on the same time two either instruments were used to calibrated the data recorded by LCU. These instruments were infrared thermometer (IRT) and soil moisture meter (SMM). The three instruments were used to measure and recorded the data each 2 {u2013} 4 hours day of six day in the week, form week 4 to week 9 for plant stage of cucumber and squash. The compression study for the data recorded by the three instruments exhibited that, there are similar trend for values according to the measure unit. The low LBT 65 mV in face of high SMC was 16% and low value of dt -2.5 {u00B0}C. Third experiment was carried in open field, using the LCU and automates drip irrigation system in the same soil and water resource of greenhouse; also the same three instruments were used in open field
530 _aIssued also as CD
653 4 _aControl
653 4 _aLaser
653 4 _aSensor
700 0 _aAyman Mahmoud Ahmed Abouelmagd ,
_eSupervisor
700 0 _aHelmy Elsayed Hassan Mohamed ,
_eSupervisor
700 0 _aMohamed Essam Eldin Shawkey ,
_eSupervisor
856 _uhttp://172.23.153.220/th.pdf
905 _aNazla
_eRevisor
905 _aShimaa
_eCataloger
942 _2ddc
_cTH
999 _c67757
_d67757