000 02890cam a2200313 a 4500
003 EG-GiCUC
008 181204s2018 ua dh f m 000 0 eng d
040 _aEG-GiCUC
_beng
_cEG-GiCUC
041 0 _aeng
049 _aDeposite
097 _aPh.D
099 _aCai01.21.06.Ph.D.2018.Em.V
100 0 _aEmad Abdelmaboud Mahmoud Elsayed Aboelnasr
245 1 0 _aValidity of clinical assessment measures of static foot posture in children /
_cEmad Abdelmaboud Mahmoud Elsayed Aboelnasr ; Supervised Hoda Abdelazim Eltalawy , Faten Hassan Abdelazim
246 1 5 _aمصداقية التقيم الاكلينيكي لقوام القدم الساكن عند الاطفال
260 _aCairo :
_bEmad Abdelmaboud Mahmoud Elsayed Aboelnasr ,
_c2018
300 _a123 P. :
_bcharts , facsimiles ;
_c25cm
502 _aThesis (Ph.D.) - Cairo University - Faculty of Physical Therapy - Department of Growth and Development Disorders in Pediatrics
520 _aBackground : Although reliability of clinical measures of static foot posture has been widely debated, validity of these measures has not been fully established especially in paediatric population. Clinicians are in need for a valid, accurate, easily used, noninvasive, safe and cost effective measure to evaluate static foot posture clinically. Objectives: To investigate validity and diagnostic accuracy of three clinical measures of static foot posture (foot posture index-6, Clarke{u2019}s angle, Normalized truncated navicular height) in children and adolescents using radiographic measures as the gold standard measure. Methods: A cross-sectional descriptive study had been conducted on a sample of 612 participants aged 6-18 years (12.36 ±3.39). Clinical assessment of static foot posture using Clarke{u2019}s angle, foot posture index-6 and normalized truncated navicular height was compared to the gold standard radiographic measures and displayed on the receiver operating characteristics curve. Intra-rater reliability was investigated using intraclass correlation coefficient. Sensitivity, specificity, predictive values, likelihood ratios were calculated for the studied clinical measures. Results: Clarke{u2019}s angle demonstrated the highest intra-rater reliability (ICC=0.99), followed by NTNH (ICC= 0.97) and FPI-6(ICC=0.96). CA was the most sensitive (98.4%) and specific (98.8%) measure and demonstrated the highest positive predictive value (97.3), negative predictive value (99.3), positive likelihood ratio (84) and the lowest negative likelihood ration (0.02) among the studied clinical measures
530 _aIssued also as CD
653 4 _aChildren
653 4 _aStatic foot posture
653 4 _aValidity
700 0 _aFaten Hassan Abdelazim ,
_eSupervisor
700 0 _aHoda Abdelazim Eltalawy ,
_eSupervisor
905 _aEnas
_eCataloger
905 _aNazla
_eRevisor
942 _2ddc
_cTH
999 _c68924
_d68924