000 03258cam a2200349 a 4500
003 EG-GiCUC
005 20250223032247.0
008 190418s2018 ua do f m 000 0 eng d
040 _aEG-GiCUC
_beng
_cEG-GiCUC
041 0 _aeng
049 _aDeposite
097 _aM.Sc
099 _aCai01.09.06.M.Sc.2018.Om.E
100 0 _aOmar Ahmed Esmat
245 1 4 _aThe effect of intrusive forces on root resorption of anterior teeth in class II division 2 deep bite cases induced by placement of mini-screw implants and Intrusive archwires :
_bA randomized clinical trial /
_cOmar Ahmed Esmat ; Supervised Amr Emad Eldakroury , Amany Hassan , Mai Hamdy Aboulfotouh
246 1 5 _aتأثير قوى تدخلية على ارتشاف الجذر للاسنان الامامية فى الصف الثاني شعبه اثنين فى حالات العضه العميقة عن طريق وضع غرسات مصغرة المسمار و قوة سلك تدخلى :
_bتجربة سريرية عشوائية
260 _aCairo :
_bOmar Ahmed Esmat ,
_c2018
300 _a108 P. :
_bcharts , photographs ;
_c25cm
502 _aThesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Orthodontics
520 _aObjectives: The aim of this study was to investigate the effect of intrusive forces generated during the treatment of deep over-bite in class II division 2 cases on root resorption, by using two different mechanics, mini-screw implants and intrusive archwire. Cone beam computed tomography (CBCT), was used in this study to determine the degree of root resorption. Materials and methods: The study design is a single center randomized clinical trial, parallel design where participants were randomly assigned to either interventional or comparison group with a 1:1 allocation ratio. No changes to the methods after trial commencement occurred. Patients were recruited from the outpatient clinic at the department of. Orthodontics, Faculty of dentistry, Cairo university from March 2015 to March 2017. This study was approved by the research ethics committee, Faculty of dentistry, Cairo university approved this study. All patients were informed about the study procedures. Results: The intrusive arch was able to efficiently intrude the anterior segment(1.14mm) in a period of 6 months. Unfortunately due to the nature of the class II division 2, some laterals werebypassed, to avoid their effects on the leveling and alignment. It was evident that the mini-screws were able to intrude the anterior teeth efficiently(1.29mm) in a period of 6 months. Either before or after treatment; Mini-screw group showed statistically significantly higher mean root length than Archwire group. As regards root resorption, there was no statistically significant difference between mean root resorption values in the two groups
530 _aIssued also as CD
653 4 _aAnterior teeth
653 4 _aMini-screw implants
653 4 _aRoot resorption
700 0 _aAmany Hassan ,
_eSupervisor
700 0 _aAmr Emad Eldakroury ,
_eSupervisor
700 0 _aMai Hamdy Aboulfotouh ,
_eSupervisor
856 _uhttp://172.23.153.220/th.pdf
905 _aNazla
_eRevisor
905 _aSamia
_eCataloger
942 _2ddc
_cTH
999 _c71538
_d71538