000 | 02796cam a2200349 a 4500 | ||
---|---|---|---|
003 | EG-GiCUC | ||
005 | 20250223032258.0 | ||
008 | 190509s2018 ua dh f m 000 0 eng d | ||
040 |
_aEG-GiCUC _beng _cEG-GiCUC |
||
041 | 0 | _aeng | |
049 | _aDeposite | ||
097 | _aM.Sc | ||
099 | _aCai01.11.31.M.Sc.2018.Na.A | ||
100 | 0 | _aNancy Osama Abdelhamid | |
245 | 1 | 4 |
_aThe additive role of contrast enhanced spectral mammography in women with risk of developing breast cancer / _cNancy Osama Abdelhamid ; Supervised Rasha Mohamed Kamal Eldin , Lamiaa Mohamed Bassam , Heba Abdulhalim Khafagy |
246 | 1 | 5 | _aالدور الأضافى لأشعه الماموجرام بالصبغة فى السيدات المعرضات للأصابة بسرطان الثدى |
260 |
_aCairo : _bNancy Osama Abdelhamid , _c2018 |
||
300 |
_a111 P. : _bcharts , facsimiles ; _c25cm |
||
502 | _aThesis (M.Sc.) - Cairo University - Faculty of Medicine - Department of Radio-diagnosis | ||
520 | _aAim of the work: To assess the additive role of contrast enhanced spectral mammography in women with risk of developing breast cancer. Patients and methods: the study included 283 eligible female patients with increased risk of developing breast cancer (i.e. positive family history of breast cancer of first degree relative, personal history of breast cancer and heterogeneously dense mammary parenchyma ), full field digital mammography (FFDM) and contrast enhanced spectral mammography (CESM) were performed, the findings were evaluated independently on both mammography and CESM scanning and final BI-RADS classifications was given in each modality and compared to histopathology results as the golden standard. Results: In total, 283women were enrolled in the study, the mean age of this study population is 48 years. Among the studied cases regardless to a specific risk factor, 15/283(5.3%) cases were diagnosed as normal, 13/283 (4.6%) cases were diagnosed as inflammatory lesions, 72/283(25.4%) cases were diagnosed as benign lesions, 6/283(2.1%) cases were diagnosed as benign precancerous lesions, and 177/283(62.5%) cases were diagnosed as malignant. The overall sensitivity of the CESM was ( 92.7 %) in this study in comparison to mammographic sensitivity (80.90%)while the specificity was (71.43 %) and (59.05 %)respectively | ||
530 | _aIssued also as CD | ||
653 | 4 | _aBIRADS classifications | |
653 | 4 | _aContrast enhanced spectral mammography | |
653 | 4 | _aFull Field digital mammography | |
700 | 0 |
_aHeba Abdulhalim Khafagy , _eSupervisor |
|
700 | 0 |
_aLamiaa Mohamed Bassam , _eSupervisor |
|
700 | 0 |
_aRasha Mohamed Kamal Eldin , _eSupervisor |
|
856 | _uhttp://172.23.153.220/th.pdf | ||
905 |
_aNazla _eRevisor |
||
905 |
_aSamia _eCataloger |
||
942 |
_2ddc _cTH |
||
999 |
_c71894 _d71894 |