245 1 0 _aTwo dimensional simulation of cement clinker cooler /
_cAmr Mostafa Kamal Mostafa ; Supervised Omar Elfarouk Abdelsalam Hassan , Seif Eddeen khaled Fateen
246 1 5 _aمحاكاة ثنائية الأبعاد لمبرد كلنكر الأسمنت
260 _aCairo :
_bAmr Mostafa Kamal Mostafa ,
_c2019
300 _a84 P. :
_bcharts , facsimiles ;
_c30cm
502 _aThesis (M.Sc.) - Cairo University - Faculty of Engineering - Department of Chemical Engineering
520 _aIn the present thesis, a mathematical model for cooling process inside clinker grate cooler is introduced and COMSOL multiphysics modeling software is used to simulate the temperature distribution of clinker and air inside clinker grate cooler.The proposed model showed that modeling softwares such as COMSOL could be used to simulate heat transfer between moving packed bed and air and significantly reduce the modeling efforts and the computational time when compared to ordinary methods which may use programming software such as Matlab during simulation.The proposed model could be used as a training tool for cement plant operator and as a guiding tool to improve cement plant operation.Temperature distribution of clinker and air in grate cooler were obtained and the results were validated using published data. Finally, the proposed model was used to study the effect of increasing the clinker bed height on the cooling process at same operation parameters
530 _aIssued also as CD
653 4 _aClinker cooler
653 4 _aMathematical modeling
653 4 _aSimulation